PURPOSE: Treatment of acute subcutaneous Achilles tendon rupture remains challenging. Whereas the results of conservative and operative treatment are inconsistent, early mobilisation treatment seems to be beneficial. Besides suture repair, operative treatment using adhesives reveals promising results. Our hypothesis was that a gluing technique provides initial stability comparable to sutures. METHODS: In a biomechanical study, 18 fresh frozen sheep Achilles tendons were used to compare the biomechanical properties of suture repair using PDS® II and Bunnell's technique to tendon gluing using BioGlue® and Tissucol®. Load to failure testing was performed. RESULTS: Ultimate failure loads of sutures (146.2 ± 30.8 N) are significantly superior to the techniques using BioGlue® (38.4 ± 18.3 N; p <0.0001) or Tissucol® (4.7 ± 2.5 N; p <0.0001). Interestingly, no significant differences in stiffness were found between the application of BioGlue® and PDS® II. CONCLUSIONS: Suture repair provides significantly superior biomechanical properties compared to the use of both tested adhesives BioGlue® and Tissucol®. Based on the presented data we recommend the use of suture material for open Achilles tendon repair.