Your browser doesn't support javascript.
loading
Can preoperative myocardial perfusion scintigraphy predict changes in left ventricular perfusion and function after coronary artery bypass graft surgery?
Eckardt, Rozy; Kjeldsen, Bo Juel; Johansen, Allan; Grupe, Peter; Haghfelt, Torben; Thayssen, Per; Andersen, Lars Ib; Hesse, Birger.
Afiliação
  • Eckardt R; Department of Cardiothoracic Surgery, Institute of Clinical Research, Odense University Hospital, Odense, Denmark. rozy@eckardtmail.dk
Interact Cardiovasc Thorac Surg ; 14(6): 779-84, 2012 Jun.
Article em En | MEDLINE | ID: mdl-22473665
ABSTRACT
OBJECTIVES We wanted to evaluate whether preoperative myocardial perfusion scintigraphy (MPS) could predict changes in cardiac symptoms and postoperative myocardial perfusion and left ventricular function after coronary artery bypass grafting (CABG). METHODS Ninety-two patients with stable angina pectoris (and at least one occluded coronary artery) underwent MPS before, and 6 months after, undergoing CABG. The result of the MPS was kept secret from the surgeons. RESULTS Before CABG, 90% of the patients had angina. After CABG, 97% of the patients were without symptoms. Overall graft patency was 84%. Before CABG, one patient had normal perfusion; in the rest of them the defects were classified as follows reversible (60%), partly reversible (27%) and irreversible (12%). Following CABG, 33% had normal perfusion; in the rest the defects were reversible in 29%, partly reversible in 12% and irreversible in 26%. Left ventricular ejection fraction (LVEF), which was normal before operation in 45%, improved in 40% of all patients. The increase in LVEF was not related to the preoperative pattern of perfusion defects. Of 30 patients with normalized perfusion after CABG, 29 (97%) had reversible defects and one patient had partly reversible defects. Of 83 perfusion defects, which were normalized after CABG, 67 were reversible (81%) or partly reversible (12%). Seventy-five percent of all reversible coronary artery territories before CABG were normalized after operation. CONCLUSIONS Our results indicate that reversible or partly reversible perfusion defects at a preoperative MPS have a high chance of normalized myocardial perfusion assessed by MPS 6 months after operation. Normal perfusion is obtained almost exclusively in territories with reversible ischaemia. Symptoms improved in nearly all patients and LVEF in a significant fraction of the patients, not related to preoperative MPS.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Volume Sistólico / Doença da Artéria Coronariana / Grau de Desobstrução Vascular / Ponte de Artéria Coronária / Função Ventricular Esquerda / Circulação Coronária / Imagem de Perfusão do Miocárdio Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Volume Sistólico / Doença da Artéria Coronariana / Grau de Desobstrução Vascular / Ponte de Artéria Coronária / Função Ventricular Esquerda / Circulação Coronária / Imagem de Perfusão do Miocárdio Idioma: En Ano de publicação: 2012 Tipo de documento: Article