Your browser doesn't support javascript.
loading
Prediction of long-term outcome of cardiac resynchronization therapy by acute pressure-volume loop measurements.
de Roest, Gerben J; Allaart, Cornelis P; Kleijn, Sebastiaan A; Delnoy, Peter Paul H M; Wu, LiNa; Hendriks, Matthijs L; Bronzwaer, Jean G F; van Rossum, Albert C; de Cock, Carel C.
Afiliação
  • de Roest GJ; Department of Cardiology, VU University Medical Center, Amsterdam, The Netherlands. gj.deroest@vumc.nl
Eur J Heart Fail ; 15(3): 299-307, 2013 Mar.
Article em En | MEDLINE | ID: mdl-23183349
ABSTRACT

AIMS:

Invasive assessment of acute haemodynamic response to biventricular pacing has been proposed as a tool to determine individual response and to optimize the effects of CRT. However, the long-term results of this approach have been poorly studied. The present study relates acute haemodynamic effects of CRT to long-term outcome. METHODS AND

RESULTS:

Forty-one patients were analysed in the present study. During temporary biventricular pacing before implantation, acute changes in LV pump function were assessed by pressure-volume loop measurements and related to long-term response after CRT. In the study population [30 (71%) men, NYHA class 2.9 ± 0.4, EF 28 ± 7%, QRS 150 ± 25 ms], baseline mean stroke work (SW) and dP/dt(max) were 4.6 ± 2.6 L × mmHg and 874 ± 259 mmHg/s, respectively. During biventricular pacing, mean SW and dP/dt(max) increased significantly by 43 ± 39% (+ 2.2 ± 2.4 L × mmHg, P < 0.001) and 13 ± 18% (+ 96 ± 136 mmHg/s, P < 0.001), respectively. In long-term responders (n = 29, 71%) compared with non-responders (n = 12, 29%), the acute increase in SW was significantly higher (+57 ± 33% vs. + 10 ± 30%, P < 0.001), whereas the acute increase in dP/dt(max) was not significantly different between responders and non-responders (+ 15 ± 18% vs. 6 ± 15%, P = 0.139). Receiver operating characteristic (ROC) curve analysis indicated that SW was superior to dP/dt(max), QRS duration and LV dyssynchrony in prediction of response to CRT. A cut-off value for SW of 20% yielded a sensitivity of 90% and specificity of 75% to predict reverse remodelling at 6 months.

CONCLUSION:

Invasive assessment of acute haemodynamics is a reliable tool to determine individual response to CRT. An acute increase in SW predicts long-term response to CRT with a higher accuracy than an acute increase in dP/dt(max), baseline QRS duration, and degree of LV mechanical dyssynchrony.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Hemodinâmica Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Hemodinâmica Idioma: En Ano de publicação: 2013 Tipo de documento: Article