Your browser doesn't support javascript.
loading
Neurosurgical procedures in the semisitting position: evaluation of the risk of paradoxical venous air embolism in patients with a patent foramen ovale.
Feigl, Guenther C; Decker, Karlheinz; Wurms, Max; Krischek, Boris; Ritz, Rainer; Unertl, Klaus; Tatagiba, Marcos.
Afiliação
  • Feigl GC; Department of Neurosurgery, University of Tübingen Medical Center, Tübingen, Germany. Electronic address: guenther.feigl@web.de.
  • Decker K; Department of Anesthesiology, University of Tübingen Medical Center, Tübingen, Germany.
  • Wurms M; Department of Neurosurgery, University of Tübingen Medical Center, Tübingen, Germany.
  • Krischek B; Department of Neurosurgery, University of Tübingen Medical Center, Tübingen, Germany.
  • Ritz R; Department of Neurosurgery, University of Tübingen Medical Center, Tübingen, Germany.
  • Unertl K; Department of Anesthesiology, University of Tübingen Medical Center, Tübingen, Germany.
  • Tatagiba M; Department of Neurosurgery, University of Tübingen Medical Center, Tübingen, Germany.
World Neurosurg ; 81(1): 159-64, 2014 Jan.
Article em En | MEDLINE | ID: mdl-23295634
ABSTRACT

OBJECTIVE:

To analyze the actual risk for patients with a patent foramen ovale (PFO) to experience a clinically relevant venous air embolism (VAE) during surgery performed in the semisitting position.

METHODS:

All procedures were performed between January 2008 and December 2009, under general anesthesia and in the semisitting position. Transesophageal echocardiography (TEE) and capnometry were used intraoperatively to monitor for air bubbles in the venous system.

RESULTS:

Of 200 consecutive patients who all were operated on in the semisitting position, 52 patients (26%) had a diagnosis of PFO. Rates of VAE in patients were graded as follows grade 0 (no air bubbles visible, no air embolism), 23 patients (44.2%); grade I (air bubbles on TEE), 22 patients (42.3%); grade II (air bubbles on TEE with decrease of end-tidal carbon dioxide [ETCO2] ≤ 3 mm Hg), 2 patients (3.8%); grade III, air bubbles on TEE with decrease of ETCO2 >3 mm Hg, 4 patients (7.7%); grade IV, air bubbles on TEE with decrease of ETCO2 >3 mm Hg and decrease of mean arterial pressure ≥ 20% or increase of heart rate ≥ 40% (or both), 1 patient (1.9%); and grade V, VAE causing arrhythmia with hemodynamic instability requiring cardiopulmonary resuscitation, 0 patients (0%). There were no deaths in this series, and no new or unexplained, mild or severe neurologic deficits were caused by a VAE.

CONCLUSIONS:

Under standardized anesthesia and neurosurgical protocols, patients with a PFO can be operated on safely in the semisitting position.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Procedimentos Neurocirúrgicos / Embolia Intracraniana / Embolia Aérea / Forame Oval Patente / Posicionamento do Paciente Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Procedimentos Neurocirúrgicos / Embolia Intracraniana / Embolia Aérea / Forame Oval Patente / Posicionamento do Paciente Idioma: En Ano de publicação: 2014 Tipo de documento: Article