Your browser doesn't support javascript.
loading
An optimised patient-specific approach to administration of contrast agent for CT pulmonary angiography.
Saade, Charbel; Bourne, Roger; El-Merhi, Fadi; Somanathan, Arjuna; Chakraborty, Dev; Brennan, Patrick.
Afiliação
  • Saade C; Department of Radiology, Royal Prince Alfred Hospital, Missenden Rd, Camperdown, 2050, Sydney, NSW, Australia, info@mdct.com.au.
Eur Radiol ; 23(11): 3205-12, 2013 Nov.
Article em En | MEDLINE | ID: mdl-23732690
OBJECTIVES: To investigate pulmonary vasculature opacification during CTPA using an optimised patient-specific protocol for administering contrast agent. METHODS: CTPA was performed on 200 patients with suspected PE. Patients were assigned to two protocol groups: protocol A, fixed 80 ml contrast agent; protocol B used a patient-specific approach. The mean cross-sectional opacification profile of 8 central and 11 peripheral pulmonary arteries and veins was measured and the arteriovenous contrast ratio (AVCR) calculated. Protocols were compared using Mann-Whitney U non-parametric statistics. Jack-knife alternative free-response receiver-operating characteristic (JAFROC) analyses assessed diagnostic efficacy. Interobserver variations were investigated using kappa methods. RESULTS: A number of pulmonary arteries demonstrated increases in opacification (P < 0.03) for protocol B compared to A, whilst opacification in the heart and veins was reduced in protocol B (P = 0.05). Increased AVCR in protocol B compared with A was observed at all anatomic locations (P < 0.0002). Increased JAFROC (P < 0.0002) and kappa variation were observed with protocol B (κ = 0.78) compared to A (κ = 0.25). Mean contrast volume was reduced in protocol B (33 ± 9 ml) compared to A (80 ± 1 ml). CONCLUSIONS: Significant improvements in visualisation of the pulmonary vasculature can be achieved with a low volume of contrast agent using injection timing based on a patient-specific contrast formula. KEY POINTS: • Optimal opacification of the pulmonary arteries is essential for CT pulmonary angiography. • Matching timing with vessel dynamics significantly improves vessel opacification. • This leads to increased arterial opacification and reduced venous opacification. • This can also lead to a reduced volume of contrast agent.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Embolia Pulmonar / Veias Pulmonares / Angiografia / Tomografia Computadorizada por Raios X / Meios de Contraste Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Embolia Pulmonar / Veias Pulmonares / Angiografia / Tomografia Computadorizada por Raios X / Meios de Contraste Idioma: En Ano de publicação: 2013 Tipo de documento: Article