Your browser doesn't support javascript.
loading
An RP-HPLC-UV method with SPE for cefotaxime in all-in-one total parenteral nutritional admixtures: application to stability studies.
Iqbal, Muhammad Shahid; Bahari, Mohd Baidi; Darwis, Yusrida; Iqbal, Muhammad Zahid; Hayat, Amer; Venkatesh, Gantala.
Afiliação
  • Iqbal MS; Universiti Sains Malaysia, School of Pharmaceutical Sciences, 11800, Pulau Pinang, Malaysia. drmmsiqbal@gmail.com
J AOAC Int ; 96(2): 290-4, 2013.
Article em En | MEDLINE | ID: mdl-23767352
ABSTRACT
A simple and selective RP-HPLC-UV method with SPE was developed and validated for the quantification of cefotaxime in all-in-one total parenteral nutrition (AIO-TPN) admixtures. Chromatographic separation was achieved on a 5 pm particle size C18 DB column (250 x 4.6 mm id) using the mobile phase ammonium acetate (25 mM, pH 4.0)-50% acetonitrile in methanol (80 + 20, v/v). The flow rate was 0.9 mL/min and the detection wavelength was 254 nm. The analyte was extracted from AIO-TPN admixtures by means of an SPE method. The cefotaxime calibration curve was linear over a concentration range of 100-1400 microg/mL with a correlation coefficient of > or = 0.9994. The intraday accuracy and precision for cefotaxime were < or = -3.15 and < or = 3.08%, respectively, whereas the interday accuracy and precision were < or = -2.48 and < or = 2.25%, respectively. The method was successfully applied to stability studies of cefotaxime in the presence of micronutrients together with low and high concentrations of macronutrients in AIO-TPN admixtures. Cefotaxime was degraded by 13.00 and 26.05% at room temperature (25 +/- 2 degrees C) after 72 h in low and high macronutrient concentration formulations of AIO-TPN admixtures, respectively. The values of cefotaxime degradation rates for low and high macronutrient concentration formulations of AIO-TPN admixtures were -0.164 and -0.353, respectively. These results indicated that there was a higher rate of degradation in the AIO-TPN admixture formulations containing high concentrations of macronutrients.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Cefotaxima / Cromatografia Líquida de Alta Pressão / Nutrição Parenteral Total / Extração em Fase Sólida / Antibacterianos Idioma: En Ano de publicação: 2013 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Cefotaxima / Cromatografia Líquida de Alta Pressão / Nutrição Parenteral Total / Extração em Fase Sólida / Antibacterianos Idioma: En Ano de publicação: 2013 Tipo de documento: Article