Your browser doesn't support javascript.
loading
Intrinsic linewidth of the plasmonic resonance in a micrometric metal mesh.
Baldassarre, L; Ortolani, M; Nucara, A; Maselli, P; Di Gaspare, A; Giliberti, V; Calvani, P.
Afiliação
  • Baldassarre L; Center for Life NanoScience@Sapienza, Istituto Italiano di Tecnologia, Viale Regina Elena 291, 00185 Rome, Italy.
Opt Express ; 21(13): 15401-8, 2013 Jul 01.
Article em En | MEDLINE | ID: mdl-23842327
ABSTRACT
The intrinsic linewidth and angular dispersion of Surface Plasmon Polariton resonance of a micrometric metal mesh have been measured with a collimated mid-infrared beam, provided by an External Cavity tunable Quantum Cascade Laser. We show that the use of a collimated beam yields an observed resonance linewidth γ = 12 cm(-1) at the resonance frequency ν0 = 1658 cm(-1), better by an order of magnitude than with a non-collimated beam. The extremely narrow plasmon resonance attained by our mesh is then exploited to reconstruct, by varying the QCL angle of incidence θ, the angular intensity distribution f(θ) of a globar at the focal plane of a conventional imaging setup. We thus show that f(θ) is better reproduced by a Gaussian distribution than by a uniform one, in agreement with ray-tracing simulation.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2013 Tipo de documento: Article