Your browser doesn't support javascript.
loading
Evaluation of diffusivity in the anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation.
Hiwatashi, A; Yoshiura, T; Togao, O; Yamashita, K; Kikuchi, K; Kobayashi, K; Ohga, M; Sonoda, S; Honda, H; Obara, M.
Afiliação
  • Hiwatashi A; Departments of Clinical Radiology.
AJNR Am J Neuroradiol ; 35(1): 95-8, 2014 Jan.
Article em En | MEDLINE | ID: mdl-23868152
ABSTRACT
BACKGROUND AND

PURPOSE:

3D turbo field echo with diffusion-sensitized driven-equilibrium preparation is a non-echo-planar technique for DWI, which enables high-resolution DWI without field inhomogeneity-related image distortion. The purpose of this study was to evaluate the feasibility of diffusion-sensitized driven-equilibrium turbo field echo in evaluating diffusivity in the normal pituitary gland. MATERIALS AND

METHODS:

First, validation of diffusion-sensitized driven-equilibrium turbo field echo was attempted by comparing it with echo-planar DWI. Five healthy volunteers were imaged by using diffusion-sensitized driven-equilibrium turbo field echo and echo-planar DWI. The imaging voxel size was 1.5 × 1.5 × 1.5 mm(3) for diffusion-sensitized driven-equilibrium turbo field echo and 1.5 × 1.9 × 3.0 mm(3) for echo-planar DWI. ADCs measured by the 2 methods in 15 regions of interests (6 in gray matter and 9 in white matter) were compared by using the Pearson correlation coefficient. The ADC in the pituitary anterior lobe was then measured in 10 volunteers by using diffusion-sensitized driven-equilibrium turbo field echo, and the results were compared with those in the pons and vermis by using a paired t test.

RESULTS:

The ADCs from the 2 methods showed a strong correlation (r = 0.79; P < .0001), confirming the accuracy of the ADC measurement with the diffusion-sensitized driven-equilibrium sequence. The ADCs in the normal pituitary gland were 1.37 ± 0.13 × 10(-3) mm(2)/s, which were significantly higher than those in the pons (1.01 ± 0.24 × 10(-3) mm(2)/s) and the vermis (0.89 ± 0.25 × 10(-3) mm(2)/s, P < .01).

CONCLUSIONS:

We demonstrated that diffusion-sensitized driven-equilibrium turbo field echo is feasible in assessing ADC in the pituitary gland.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hipófise / Algoritmos / Interpretação de Imagem Assistida por Computador / Imagem Ecoplanar / Imageamento Tridimensional / Imagem de Difusão por Ressonância Magnética Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hipófise / Algoritmos / Interpretação de Imagem Assistida por Computador / Imagem Ecoplanar / Imageamento Tridimensional / Imagem de Difusão por Ressonância Magnética Idioma: En Ano de publicação: 2014 Tipo de documento: Article