Your browser doesn't support javascript.
loading
Revealing molecular structure and orientation with Stokes vector resolved second harmonic generation microscopy.
Mazumder, Nirmal; Hu, Chih-Wei; Qiu, Jianjun; Foreman, Matthew R; Romero, Carlos Macías; Török, Peter; Kao, Fu-Jen.
Afiliação
  • Mazumder N; Institute of Biophotonics, National Yang-Ming University, Taipei 11221, Taiwan, ROC.
  • Hu CW; Institute of Biophotonics, National Yang-Ming University, Taipei 11221, Taiwan, ROC.
  • Qiu J; Institute of Biophotonics, National Yang-Ming University, Taipei 11221, Taiwan, ROC.
  • Foreman MR; Blackett Laboratory, Department of Physics, Imperial College London, Prince Consort Road, London SW7 2BZ, UK; Max Planck Institute for the Science of Light, Günther-Scharowsky-Straße 1, 91058 Erlangen, Germany.
  • Romero CM; Ecole Polytechnique Fedérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Török P; Blackett Laboratory, Department of Physics, Imperial College London, Prince Consort Road, London SW7 2BZ, UK.
  • Kao FJ; Institute of Biophotonics, National Yang-Ming University, Taipei 11221, Taiwan, ROC. Electronic address: fjkao@ym.edu.tw.
Methods ; 66(2): 237-45, 2014 Mar 15.
Article em En | MEDLINE | ID: mdl-23891802
ABSTRACT
We report on measurements and characterization of polarization properties of Second Harmonic (SH) signals using a four-channel photon counting based Stokes polarimeter. In this way, the critical polarization parameters can be obtained concurrently without the need of repeated image acquisition. The critical polarization parameters, including the degree of polarization (DOP), the degree of linear polarization (DOLP), and the degree of circular polarization (DOCP), are extracted from the reconstructed Stokes vector based SH images in a pixel-by-pixel manner. The measurements are further extended by varying the polarization states of the incident light and recording the resulting Stokes parameters of the SH signal. In turn this allows the molecular structure and orientation of the samples to be determined. Use of Stokes polarimetry is critical in determination of the full polarization state of light, and enables discrimination of material properties not possible with conventional crossed-polarized detection schemes. The combination of SHG microscopy and Stokes polarimeter hence makes a powerful tool to investigate the structural order of targeted specimens.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colágeno Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colágeno Idioma: En Ano de publicação: 2014 Tipo de documento: Article