Your browser doesn't support javascript.
loading
A case of large anterior paraclinoid aneurysm with intraoperative premature rupture.
Ichimura, Shinya; Inaba, Makoto; Kagami, Hiroshi.
Afiliação
  • Ichimura S; Department of Neurosurgery, Saiseikai Yokohamashi Tobu Hospital, Yokohama, Japan.
J Neurol Surg Rep ; 73(1): 48-51, 2012 Oct.
Article em En | MEDLINE | ID: mdl-23946926
ABSTRACT
We report here troubleshooting of intraoperative premature rupture with large anterior paraclinoid aneurysm, which was successfully clipped. A 61-year-old woman with left nasal hemianopia was referred to our institute. Preoperative three-dimensional computed tomography angiography and a left internal carotid artery angiogram showed a large left anterior clinoid aneurysm adjacent to the anterior clinoid process. Aneurysm was ruptured prematurely and tentative clipping of the dome of the aneurysm was done incidentally to stop bleeding and to reduce the volume of the aneurysm. The anterior clinoid process and superior wall of the orbit were drilled out safely, since the tentative clipping had created sufficient space between the aneurysm and the anterior clinoid process to perform the procedure. The proximal neck was observed and tandem clipping was applied to the aneurysm. Intraoperative and postoperative angiography revealed complete disappearance of the aneurysm.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2012 Tipo de documento: Article