Your browser doesn't support javascript.
loading
Multi-Stencil Streamline Fast Marching: A General 3-D Framework to Determine Myocardial Thickness and Transmurality in Late Enhancement Images.
IEEE Trans Med Imaging ; 33(1): 23-37, 2014 Jan.
Article em En | MEDLINE | ID: mdl-24235299
We propose a fully 3-D methodology for the computation of myocardial nonviable tissue transmurality in contrast enhanced magnetic resonance images. The outcome is a continuous map defined within the myocardium where not only current state-of-the-art measures of transmurality can be calculated, but also information on the location of nonviable tissue is preserved. The computation is done by means of a partial differential equation framework we have called multi-stencil streamline fast marching. Using it, the myocardial and scarred tissue thickness is simultaneously computed. Experimental results show that the proposed 3-D method allows for the computation of transmurality in myocardial regions where current 2-D methods are not able to as conceived, and it also provides more robust and accurate results in situations where the assumptions on which current 2-D methods are based-i.e., there is a visible endocardial contour and its corresponding epicardial points lie on the same slice-, are not met.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Miocárdio Atordoado / Meios de Contraste / Imageamento Tridimensional Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Miocárdio Atordoado / Meios de Contraste / Imageamento Tridimensional Idioma: En Ano de publicação: 2014 Tipo de documento: Article