Left ventricular torsion abnormalities in septic shock and corrective effect of volume loading: a pilot study.
Bloechlinger, Stefan; Berger, David; Bryner, Jürg; Wiegand, Jan; Dünser, Martin W; Takala, Jukka.
Afiliação
  • Bloechlinger S; Department of Intensive Care Medicine, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland; Department of Cardiology, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland. Electronic address: Stefan.Bloechlinger@insel.ch.
Can J Cardiol ; 29(12): 1665-71, 2013 Dec.
Article em En | MEDLINE | ID: mdl-24267806
ABSTRACT

BACKGROUND:

Ventricular torsion is an important component of cardiac function. The effect of septic shock on left ventricular torsion is not known. Because torsion is influenced by changes in preload, we compared the effect of fluid loading on left ventricular torsion in septic shock with the response in matched healthy control subjects.

METHODS:

We assessed left ventricular torsion parameters using transthoracic echocardiography in 11 patients during early septic shock and in 11 age- and sex-matched healthy volunteers before and after rapid volume loading with 250 mL of a Ringer's lactate solution.

RESULTS:

Peak torsion and peak apical rotation were reduced in septic shock (10.2 ± 5.2° and 5.6 ± 5.4°) compared with healthy volunteers (16.3 ± 4.5° and 9.6 ± 1.5°; P = 0.009 and P = 0.006 respectively). Basal rotation was delayed and diastolic untwisting velocity reached its maximum later during diastole in septic shock patients than in healthy volunteers (104 ± 16% vs 111 ± 14% and 13 ± 5% vs 21 ± 10%; P = 0.03 and P = 0.034, respectively). Fluid challenge increased peak torsion in both groups (septic shock, 10.2 ± 5.3° vs 12.6 ± 3.9°; healthy volunteers, 16.3 ± 4.5° vs 18.1 ± 6°; P = 0.01). Fluid challenge increased left ventricular stroke volume in septic shock patients (P = 0.003).

CONCLUSIONS:

Compared with healthy volunteers, left ventricular torsion is impaired in septic shock patients. Fluid loading attenuates torsion abnormalities in parallel with increasing stroke volume. Reduced torsional motion might constitute a relevant component of septic cardiomyopathy, a notion that merits further testing in larger populations.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Choque Séptico / Anormalidade Torcional / Disfunção Ventricular Esquerda / Hidratação Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Choque Séptico / Anormalidade Torcional / Disfunção Ventricular Esquerda / Hidratação Idioma: En Ano de publicação: 2013 Tipo de documento: Article