[Three-dimensional finite element analysis of acetabular prosthesis in an adult patient with total flip arthroplasty for high dislocation].
Cheng, Xing-Wang; Lan, Ping-Wen; Shen, Bin; Liu, Zhan; Zhang, Yuan-Li; Yang, Jing; Zhou, Zong-Ke; Kang, Peng-De; Pei, Fuxing.
Afiliação
  • Cheng XW; Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu 610041, China.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 44(5): 787-91, 2013 Sep.
Article em Zh | MEDLINE | ID: mdl-24325113
OBJECTIVE: To observe stress distributions around the acetabular prosthesis and the bones of a patient who underwent total hip arthroplasty (THA). METHODS: Finite element analysis (FEA) was performed with an osteoarthritis patient who underwent THA for her secondary hip high dislocations: Scenario A--deepened acetabulum at the true acetabulum with a small 44 mm cup; Scenario B--structural bone graft at lateral acetabular with a 48 mm cup; Scenario C--place tantalum metal acetabular reconstruction at the lateral acetabular with a 48 mm cup; Scenario D--the normal side of the hip. According to the Wasielewski methods, acetabular was divided into four zones, in the same way on the lining surface. Ten points were taken in each zone for measuring the Von Mises stress values. RESULTS: Scenario A generated significantly greater stress values in the bones in zone one than the other three scenarios. Significantly greater stress was also found in the inner surface of polyethylene over all of the four zones under scenario A compared with those of the scenario B and C, especially in zone one and two. The cup initial micro-mobility for scenario A was 49. 18 microm, 19 times of that of scenario B and 8 times of that of scenario C. CONCLUSION: (1) Deepened acetabulum with small cup can cause stress concentration in the acetabular bones and liner, leading to large cup initial micro-mobility. (2) Acetabular lateral structural bone grafting and placement of tantalum metal reconstruction have better biomechanical properties, which can enable the use of bigger cups.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Análise de Elementos Finitos / Luxação do Quadril / Prótese de Quadril / Acetábulo Idioma: Zh Ano de publicação: 2013 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Análise de Elementos Finitos / Luxação do Quadril / Prótese de Quadril / Acetábulo Idioma: Zh Ano de publicação: 2013 Tipo de documento: Article