Your browser doesn't support javascript.
loading
The stability following advancement genioplasty with biodegradable screw fixation.
Lee, Gyu-Tae; Jung, Hwi-Dong; Kim, Sang Yoon; Park, Hyung-Sik; Jung, Young-Soo.
Afiliação
  • Lee GT; Department of Oral & Maxillofacial Surgery, Oral Science Research Institute, Yonsei University College of Dentistry, Seoul, Republic of Korea. Electronic address: 266681@yuhs.ac.
  • Jung HD; Department of Oral & Maxillofacial Surgery, Oral Science Research Institute, Yonsei University College of Dentistry, Seoul, Republic of Korea. Electronic address: cancer7@yuhs.ac.
  • Kim SY; Private Practice, Vienna, VA, USA. Electronic address: drsangkim@gmail.com.
  • Park HS; Department of Oral & Maxillofacial Surgery, Oral Science Research Institute, Yonsei University College of Dentistry, Seoul, Republic of Korea. Electronic address: hspark709@yuhs.ac.
  • Jung YS; Department of Oral & Maxillofacial Surgery, Oral Science Research Institute, Yonsei University College of Dentistry, Seoul, Republic of Korea. Electronic address: ysjoms@yuhs.ac.
Br J Oral Maxillofac Surg ; 52(4): 363-8, 2014 Apr.
Article em En | MEDLINE | ID: mdl-24485052
ABSTRACT
The purpose of this study was to compare postoperative stability using biodegradable screws with that of metal plates for fixation of advancement genioplasty. We studied patients who had advancement genioplasty alone or at the same time as other orthognathic surgery including mandibular setback. We assessed the lateral cephalographs at different time points (preoperatively, and 7 days, 3 months, 6 months, and 12 months postoperatively). A total of 54 patients were enrolled and 27 patients were assigned to each group. The position of pogonion was stable 12 months postoperatively, and the amount of skeletal advancement was reflected in soft tissue close to 100%. There were no clinical differences between biodegradable screws and conventional metal plates used for fixation. Biodegradable fixation for advancement genioplasty is a good option for patients who would require a second operation for removal of the plates.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Parafusos Ósseos / Queixo / Implantes Absorvíveis / Mentoplastia Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Parafusos Ósseos / Queixo / Implantes Absorvíveis / Mentoplastia Idioma: En Ano de publicação: 2014 Tipo de documento: Article