Your browser doesn't support javascript.
loading
Chemomechanical preparation by hand instrumentation and by Mtwo engine-driven rotary files, an ex vivo study.
Krajczár, Károly; Tigyi, Zoltán; Papp, Viktória; Marada, Gyula; Sára, Jeges; Tóth, Vilmos.
Afiliação
  • Krajczár K; DMD. Clinical Consultant. Dental School, Faculty of Medicine, University of Pécs, Hungary.
  • Tigyi Z; MD, PhD Associate Professor. Department of Medical Microbiology and Immunology, Faculty of Medicine, University of Pécs, Hungary.
  • Papp V; DMD. Private practice, Nagykanizsa, Hungary.
  • Marada G; DMD. Assistant Professor. Dental School, Faculty of Medicine, University of Pécs, Hungary.
  • Sára J; BSc, MSc, PhD. Professor. Department of Biostatistics and Health Informatics, Faculty of Health Sciences, University of Pécs, Hungary.
  • Tóth V; DMD, PhD. Professor. Dental School, Faculty of Medicine, University of Pécs, Hungary.
J Clin Exp Dent ; 4(3): e146-50, 2012 Jul.
Article em En | MEDLINE | ID: mdl-24558545
ABSTRACT

OBJECTIVE:

To compare the disinfecting efficacy of the sodium hypochlorite irrigation by root canal preparation with stainless steel hand files, taper 0.02 and nickel-titanium Mtwo files with taper 0.04-0.06. STUDY

DESIGN:

40 extracted human teeth were sterilized, and then inoculated with Enterococcus faecalis (ATCC 29212). After 6 day incubation time the root canals were prepared by hand with K-files (n=20) and by engine-driven Mtwo files (VDW, Munich, Germany) (n=20). Irrigation was carried out with 2.5% NaOCl in both cases. Samples were taken and determined in colony forming units (CFU) from the root canals before and after the preparation with instruments #25 and #35.

RESULTS:

Significant reduction in bacterial count was determined after filing at both groups. The number of bacteria kept on decreasing with the extension of apical preparation diameter. There was no significant difference between the preparation sizes in the bacterial counts after hand or engine-driven instrumentation at the same apical size. Statistical analysis was carried out with Mann-Whitney test, paired t-test and independent sample t-test.

CONCLUSIONS:

Significant reduction in CFU was achieved after the root canal preparation completed with 2.5% NaOCl irrigation, both with stainless steel hand or nickel-titanium rotary files. The root canal remained slightly infected after chemo mechanical preparation in both groups. Key wordsChemomechanical preparation, root canal disinfection, nickel-titanium, conicity, greater taper, apical size.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2012 Tipo de documento: Article