Your browser doesn't support javascript.
loading
A chitosan-polypyrrole magnetic nanocomposite as µ-sorbent for isolation of naproxen.
Bagheri, Habib; Roostaie, Ali; Baktash, Mohammad Yahya.
Afiliação
  • Bagheri H; Environmental and Bio-Analytical Laboratories, Department of Chemistry, Sharif University of Technology, PO Box 11365-9516, Tehran, Iran. Electronic address: bagheri@sharif.edu.
  • Roostaie A; Environmental and Bio-Analytical Laboratories, Department of Chemistry, Sharif University of Technology, PO Box 11365-9516, Tehran, Iran.
  • Baktash MY; Environmental and Bio-Analytical Laboratories, Department of Chemistry, Sharif University of Technology, PO Box 11365-9516, Tehran, Iran.
Anal Chim Acta ; 816: 1-7, 2014 Mar 13.
Article em En | MEDLINE | ID: mdl-24580849
ABSTRACT
An extracting medium based on chitosan-polypyrrole (CS-PPy) magnetic nanocomposite was synthesized by chemical polymerization of pyrrole at the presence of chitosan magnetic nanoparticles (CS-MNPs) for micro-solid phase extraction. In this work, magnetic nanoparticles, the modified CS-MNPs and different types of CS-PPy magnetic nanocomposites were synthesized. Extraction efficiency of the CS-PPy magnetic nanocomposite was compared with the CS-MNPs and Fe3O4 nanoparticles for the determination of naproxen in aqueous samples, via quantification by spectrofluorimetry. The scanning electron microscopy images obtained from all the prepared nanocomposites revealed that the CS-PPy magnetic nanocomposite possess more porous structure. Among different synthesized magnetic nanocomposites, CS-PPy magnetic nanocomposite showed a prominent efficiency. Influencing parameters on the morphology of CS-PPy magnetic nanocomposite such as weight ratio of components was also assayed. In addition, effects of different parameters influencing the extraction efficiency of naproxen including desorption solvent, desorption time, amount of sorbent, ionic strength, sample pH and extraction time were investigated and optimized. Under the optimum condition, a linear calibration curve in the range of 0.04-10 µg mL(-1) (R(2)=0.9996) was obtained. The limits of detection (3Sb) and limits of quantification (10Sb) of the method were 0.015 and 0.04 µg mL(-1) (n=3), respectively. The relative standard deviation for water sample spiked with 0.1 µg mL(-1) of naproxen was 3% (n=5) and the absolute recovery was 92%. The applicability of method was extended to the determination of naproxen in tap water, human urine and plasma samples. The relative recovery percentages for these samples were in the range of 56-99%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Pirróis / Naproxeno / Quitosana / Nanopartículas de Magnetita Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Pirróis / Naproxeno / Quitosana / Nanopartículas de Magnetita Idioma: En Ano de publicação: 2014 Tipo de documento: Article