Your browser doesn't support javascript.
loading
Vitamin E and vitamin E acetate absorption from self-assembly systems under pancreas insufficiency conditions.
Nagy, Kornél; Lobo, Beatriz; Courtet-Compondu, Marie-Claude; Braga-Lagache, Sophie; Ramos, Laura; Puig-Divi, Valentí; Azpiroz, Fernando; Malagelada, Juan Ramón; Beaumont, Maurice; Moulin, Julie; Acquistapace, Simone; Sagalowicz, Laurent; Kussmann, Martin; Santos, Javier; Holst, Birgit; Williamson, Gary.
Afiliação
  • Nagy K; Nestlé Research Center, Nestec Ltd., Lausanne, Switzerland.
  • Lobo B; Digestive System Research Unit, Institut de Recerca Vall d'Hebron; Department of Gastroenterology, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona (Department of Medicine), Barcelona, Spain.
  • Courtet-Compondu MC; Nestlé Research Center, Nestec Ltd., Lausanne, Switzerland.
  • Braga-Lagache S; Nestlé Research Center, Nestec Ltd., Lausanne, Switzerland.
  • Ramos L; Digestive System Research Unit, Institut de Recerca Vall d'Hebron; Department of Gastroenterology, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona (Department of Medicine), Barcelona, Spain.
  • Puig-Divi V; Digestive Diseases Unit, Hospital de Sabadell, Institut Universitari Parc Taulí, Universitat Autònoma de Barcelona, Sabadell, Spain.
  • Azpiroz F; Digestive System Research Unit, Institut de Recerca Vall d'Hebron; Department of Gastroenterology, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona (Department of Medicine), Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBER
  • Malagelada JR; Digestive System Research Unit, Institut de Recerca Vall d'Hebron; Department of Gastroenterology, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona (Department of Medicine), Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBER
  • Beaumont M; Nestlé Research Center, Nestec Ltd., Lausanne, Switzerland.
  • Moulin J; Nestlé Research Center, Nestec Ltd., Lausanne, Switzerland.
  • Acquistapace S; Nestlé Research Center, Nestec Ltd., Lausanne, Switzerland.
  • Sagalowicz L; Nestlé Research Center, Nestec Ltd., Lausanne, Switzerland.
  • Kussmann M; Molecular Biomarkers Core, Nestlé Institute of Health Sciences, Campus EPFL, Quartier de l'innovation, bâtiment H, CH-1015 Lausanne, Switzerland; Ecole Polytechnique Fédérale Lausanne (EPFL), Lausanne, Switzerland; Faculty of Science, Aarhus University, Aarhus, Denmark.
  • Santos J; Digestive System Research Unit, Institut de Recerca Vall d'Hebron; Department of Gastroenterology, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona (Department of Medicine), Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBER
  • Holst B; Nestlé Research Center, Nestec Ltd., Lausanne, Switzerland.
  • Williamson G; School of Food Science and Nutrition, University of Leeds, Leeds, UK.
Chimia (Aarau) ; 68(3): 129-34, 2014.
Article em En | MEDLINE | ID: mdl-24801842
ABSTRACT
We determined the bioavailability of vitamin E from self-assembly structures in patients with diagnosed chronic pancreas insufficiency. Vitamin E solubilized in dispersed inverted bicontinuous cubic phase and in micellar formulation was delivered directly to the small intestine by tube-feeding. A cross-over study with randomization of 6 subjects and 2 treatments including a combined dose of 18 mg (27 IU) of vitamin E (RRR-[5,7-methyl-((2)H6)]-α-tocopherol) and 27 mg (27 IU) vitamin E acetate (RRR-[5-methyl-(2)H3]-α-tocopheryl acetate) was applied over a time period of 1 h. Plasma samples were collected for 56 h and analyzed by liquid chromatography-mass spectrometry. Appearance of labeled tocopherols originating from the treatment started at 25 h and reached Cmax (0.6-4.6 µM depending on subject) in the 7-9 h window. From the Tmax onwards, both forms of tocopherols diminished slowly to 30-50% of their maxima within 56 h. Strong inter-individual variation was observed in the plasma appearance curves (relative standard deviation varied between 38-45%). No significant discrimination was found between the absorption of free or acetylated forms of deuterated α-tocopherol confirming that application of acetylated α-tocopherol provides the same bioavailability as free α-tocopherol. This observation is valid in both dispersed inverted bicontinuous cubic phase and micellar formulations. Furthermore, since the area-under-the-curve values from cubic phase and from micellar formulations are similar, the cubic phase formulation could represent an alternative delivery system for lipophilic micronutrients in conditions or studies where polysorbate-based micelles cannot be generated.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência Pancreática Exócrina / Vitamina E / Sistemas de Liberação de Medicamentos / Antioxidantes Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência Pancreática Exócrina / Vitamina E / Sistemas de Liberação de Medicamentos / Antioxidantes Idioma: En Ano de publicação: 2014 Tipo de documento: Article