Your browser doesn't support javascript.
loading
Evaluation of gastric emptying in diabetic gastropathy by an ultrasonic whole stomach cylinder method.
Shen, Hao-Lin; Yang, Shu-Ping; Hong, Li-Wei; Lin, Li-Qing; Wang, Kang-Jian; Cai, Xiao-Han; Lv, Guo-Rong.
Afiliação
  • Shen HL; Department of Ultrasound, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian, China; Department of Ultrasound, Zhangzhou Hospital Affiliated to Fujian Medical University, Zhangzhou, Fujian, China.
  • Yang SP; Department of Ultrasound, Zhangzhou Hospital Affiliated to Fujian Medical University, Zhangzhou, Fujian, China.
  • Hong LW; Department of Nuclear Medicine, Zhangzhou Hospital Affiliated to Fujian Medical University, Zhangzhou, Fujian, China.
  • Lin LQ; Department of Ultrasound, Zhangzhou Hospital Affiliated to Fujian Medical University, Zhangzhou, Fujian, China.
  • Wang KJ; Department of Ultrasound, Zhangzhou Hospital Affiliated to Fujian Medical University, Zhangzhou, Fujian, China.
  • Cai XH; Department of Ultrasound, Zhangzhou Hospital Affiliated to Fujian Medical University, Zhangzhou, Fujian, China.
  • Lv GR; Department of Ultrasound, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian, China; Department of Clinical Medicine, Quanzhou Medical College, Quanzhou, Fujian, China. Electronic address: lgr_feus@sina.com.
Ultrasound Med Biol ; 40(9): 1998-2003, 2014 Sep.
Article em En | MEDLINE | ID: mdl-25023116
ABSTRACT
In order to explore the accuracy of ultrasonic whole stomach cylinder measurement (UWSCM) in the evaluation of gastric emptying, we measured the gastric emptying times (ET) at 25% (T1), 50% (T2) and 75% (T3) of healthy subjects and patients with diabetic gastropathy by UWSCM and scintigraphy. The ET of patients were compared with their clinical symptom scores. We found that the ET measured by UWSCM showed no significant difference with scintigraphy (p > 0.05). The correlation between them was good, and the correlation coefficient of T3 reached 0.744 (p < 0.05). All emptying times in the diabetic patients were longer than those in the healthy subjects (p < 0.05). The T3 in the diabetic group measured by UWSCM had the best correlation with the symptom index (r = 0.469, p < 0.05). We conclude that ET measured by UWSCM is accurate and T3 combining the symptoms index provides an accurate clinical basis for gastropathy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estômago / Diabetes Mellitus / Esvaziamento Gástrico Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estômago / Diabetes Mellitus / Esvaziamento Gástrico Idioma: En Ano de publicação: 2014 Tipo de documento: Article