Radiation exposure from head computed tomography scans in pediatric trauma.
Sharp, Nicole E; Svetanoff, Wendy J; Desai, Amita; Alemayehu, Hanna; Raghavan, Maneesha U; Sharp, Susan W; Brown, James C; Rivard, Douglas C; St Peter, Shawn D; Holcomb, George W.
Afiliação
  • Sharp NE; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri.
  • Svetanoff WJ; Department of Surgery, Creighton University, Omaha, Nebraska.
  • Desai A; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri.
  • Alemayehu H; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri.
  • Raghavan MU; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri.
  • Sharp SW; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri.
  • Brown JC; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri.
  • Rivard DC; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri.
  • St Peter SD; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri.
  • Holcomb GW; Department of Surgery, The Children's Mercy Hospital, Kansas City, Missouri. Electronic address: gholcomb@cmh.edu.
J Surg Res ; 192(2): 276-9, 2014 Dec.
Article em En | MEDLINE | ID: mdl-25082747
ABSTRACT

BACKGROUND:

We have previously reported that children receive significantly less radiation exposure after abdominal and/or pelvis computed tomography (CT) scanning for acute appendicitis when performed at our children's hospital (CH) rather than at outside hospitals (OH). In this study, we compare the amount of radiation children receive from head CTs for trauma done at OH versus those at our CH.

METHODS:

A retrospective chart review was performed on all children transferred to our hospital after receiving a head CT for trauma at an OH between July 2012 and December 2012. These children were then blindly case matched based on date, age, and gender to children at our CH.

RESULTS:

There were 50 children who underwent head CT scans for trauma at 28 OH. There were 21 females and 29 males in each group. Average age was 7.01 ± 0.5 y at the OH and 7.14 ± 6.07 at our CH (P = 0.92). Average weight was 30.81 ± 4.69 kg at the OH and 32.69 ± 27.21 kg at our CH (P = 0.81). Radiation measures included dose length product (671.21 ± 22.6 mGycm at OH versus 786.28 ± 246.3 mGycm at CH, P = 0.11) and CT dose index (53.4 ± 2.26 mGy at OH versus 49.2 ± 12.94 mGy at CH, P = 0.56).

CONCLUSIONS:

There is no significant difference between radiation exposure secondary to head CTs for traumatic injuries performed at OH and those at a dedicated CH.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Traumatismos Craniocerebrais Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Traumatismos Craniocerebrais Idioma: En Ano de publicação: 2014 Tipo de documento: Article