Your browser doesn't support javascript.
loading
In situ exposure assessment of intermediate frequency fields of diverse devices.
Van Den Bossche, Matthias; Verloock, Leen; Aerts, Sam; Joseph, Wout; Martens, Luc.
Afiliação
  • Van Den Bossche M; Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium.
  • Verloock L; Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium.
  • Aerts S; Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium.
  • Joseph W; Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium wout.joseph@intec.ugent.be.
  • Martens L; Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium.
Radiat Prot Dosimetry ; 164(3): 252-64, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25125596
ABSTRACT
In this study, in situ exposure assessment of both electric and magnetic fields of different intermediate frequency (IF) sources is investigated. The authors investigated smart boards and touchscreens, energy-saving bulbs, fluorescent lamps, a portable hearing unit and an electrosurgical unit (ESU). For most of these sources, the electric field is the dominating quantity. International Commission on Non-Ionizing Radiation Protection reference levels are exceeded for touchscreens (44 kHz up to 155.7 V m(-1) at 5 cm), energy-saving bulbs (38-52 kHz up to 117.3 V m(-1)), fluorescent lamps (52 kHz up to 471 V m(-1) at 5 cm) and ESUs (up to 920 kHz 792 V m(-1) at 0.5 cm). Magnetic field strengths up to 1.8 and 10.5 A m(-1) were measured close to the ESU and portable hearing unit (69 V m(-1)), respectively. Large differences of measured field values exist among the various operating modes of the IF equipment. Compliance distances for general public range from 15.3 cm (touchscreen) to 25 cm (fluorescent lamps).
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Monitoramento de Radiação / Exposição Ocupacional / Campos Eletromagnéticos / Exposição Ambiental Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Monitoramento de Radiação / Exposição Ocupacional / Campos Eletromagnéticos / Exposição Ambiental Idioma: En Ano de publicação: 2015 Tipo de documento: Article