Your browser doesn't support javascript.
loading
Migration of a retained temporary epicardial pacing wire into an abdominal aortic aneurysm.
Mukaihara, Kosuke; Yotsumoto, Goichi; Matsumoto, Kazuhisa; Imoto, Yutaka.
Afiliação
  • Mukaihara K; Department of Cardiovascular and Gastroenterological Surgery, Kagoshima University, Kagoshima, Japan kousuke@m3.kufm.kagoshima-u.ac.jp.
  • Yotsumoto G; Department of Cardiovascular and Gastroenterological Surgery, Kagoshima University, Kagoshima, Japan.
  • Matsumoto K; Department of Cardiovascular and Gastroenterological Surgery, Kagoshima University, Kagoshima, Japan.
  • Imoto Y; Department of Cardiovascular and Gastroenterological Surgery, Kagoshima University, Kagoshima, Japan.
Eur J Cardiothorac Surg ; 48(1): 169-70, 2015 Jul.
Article em En | MEDLINE | ID: mdl-25173602

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estimulação Cardíaca Artificial / Migração de Corpo Estranho / Aneurisma da Aorta Abdominal Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estimulação Cardíaca Artificial / Migração de Corpo Estranho / Aneurisma da Aorta Abdominal Idioma: En Ano de publicação: 2015 Tipo de documento: Article