Your browser doesn't support javascript.
loading
Glucose biosensing using glassy carbon electrode modified with polyhydroxy-C60, glucose oxidase and ionic-liquid.
Yang, Tian; Yang, Xiao-Lu; Zhang, Yu-Shuai; Xiao, BaoLin; Hong, Jun.
Afiliação
  • Yang T; School of Life Sciences, Henan University, Kaifeng 475000, China.
  • Yang XL; School of Life Sciences, Henan University, Kaifeng 475000, China.
  • Zhang YS; School of Life Sciences, Henan University, Kaifeng 475000, China.
  • Xiao B; School of Life Sciences, Henan University, Kaifeng 475000, China.
  • Hong J; School of Life Sciences, Henan University, Kaifeng 475000, China Institute of Biotechnology, Henan University, Kaifeng 475000, China.
Biomed Mater Eng ; 24(6): 2197-202, 2014.
Article em En | MEDLINE | ID: mdl-25226918
Direct electrochemistry of glucose oxidase (GOD) was achieved when an ionic liquid/GOD-Polyhydroxy-C60 functional membrane was confined on a glassy carbon electrode (GCE). The cyclic voltammograms (CVs) of the modified GCE showed a pair of redox peaks with a formal potential (E°') of - 329 ± 2 mV. The heterogeneous electron transfer constant (k(s)) was 1.43 s-1. The modified GCE response to glucose was linear in the range from 0.02 to 2.0 mM. The detection limit was 1 µM. The apparent Michaelis-Menten constant (K(m)(app)) was 1.45 mM.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácidos Carboxílicos / Técnicas Biossensoriais / Condutometria / Fulerenos / Eletrodos / Líquidos Iônicos / Glucose / Glucose Oxidase Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácidos Carboxílicos / Técnicas Biossensoriais / Condutometria / Fulerenos / Eletrodos / Líquidos Iônicos / Glucose / Glucose Oxidase Idioma: En Ano de publicação: 2014 Tipo de documento: Article