Your browser doesn't support javascript.
loading
Dielectric relaxation of normothermic and hypothermic rat corneas.
Marzec, E; Sosnowski, P; Olszewski, J; Krauss, H; Bahloul, K; Samborski, W; Krawczyk-Wasielewska, A.
Afiliação
  • Marzec E; Department of Bionics and Bioimpedance, University of Medical Sciences, Parkowa 2, 60-775 Poznan, Poland. Electronic address: ewaklcde@amu.edu.pl.
  • Sosnowski P; Department of Physiology, University of Medical Sciences, Swiecickiego 6, 60-781 Poznan, Poland.
  • Olszewski J; Department of Bionics and Bioimpedance, University of Medical Sciences, Parkowa 2, 60-775 Poznan, Poland.
  • Krauss H; Department of Physiology, University of Medical Sciences, Swiecickiego 6, 60-781 Poznan, Poland.
  • Bahloul K; Certus Hospital, Grunwaldzka 165, Poznan, Poland.
  • Samborski W; Department of Physiotherapy, Rheumatology and Rehabilitation, University of Medical Sciences, 28 Czerwca 1958r., 60-545 Poznan, Poland.
  • Krawczyk-Wasielewska A; Department of Physiotherapy, Rheumatology and Rehabilitation, University of Medical Sciences, 28 Czerwca 1958r., 60-545 Poznan, Poland.
Bioelectrochemistry ; 101: 132-7, 2015 Feb.
Article em En | MEDLINE | ID: mdl-25308935
ABSTRACT
This paper aims at the presentation of the results of in vitro research on the dielectric properties of the cornea specimen collected from the rats subjected to in vivo hypothermia. The average values of the relative permittivity and dielectric loss are about 40% higher for the hypothermic cornea than those for the normothermic tissue at the same water content of 12% for both samples and at 25°C. Whereas, at 50°C this effect of increase in the dielectric properties of the hypothermic cornea when compared to the normothermic one is observed clearly only in the relative permittivity of about 19%. In the temperature range of 25-50°C, the activation energy of conductivity associated with the release of loosely bound water takes the average values of 45kJ/mol and 30kJ/mol for the normothermic and hypothermic corneas, respectively. The study provided information on dielectric polarization and conductance mechanisms in the cornea which may be helpful in interpreting clinical results of human cornea examination, currently obtained by means of such electrodiagnostic methods as conductive keratoplasty, electroretinography or electrooculography.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Córnea / Hipotermia Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Córnea / Hipotermia Idioma: En Ano de publicação: 2015 Tipo de documento: Article