Your browser doesn't support javascript.
loading
The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering.
Braicovich, L; Minola, M; Dellea, G; Le Tacon, M; Moretti Sala, M; Morawe, C; Peffen, J-Ch; Supruangnet, R; Yakhou, F; Ghiringhelli, G; Brookes, N B.
Afiliação
  • Braicovich L; CNR-SPIN and Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo Da Vinci 32, Milano I-20133, Italy.
  • Minola M; CNR-SPIN and Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo Da Vinci 32, Milano I-20133, Italy.
  • Dellea G; CNR-SPIN and Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo Da Vinci 32, Milano I-20133, Italy.
  • Le Tacon M; Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart, Germany.
  • Moretti Sala M; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble F-38043, France.
  • Morawe C; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble F-38043, France.
  • Peffen JC; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble F-38043, France.
  • Supruangnet R; Synchrotron Light Research Institute, Nakhon Ratchasima, Thailand.
  • Yakhou F; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble F-38043, France.
  • Ghiringhelli G; CNR-SPIN and Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo Da Vinci 32, Milano I-20133, Italy.
  • Brookes NB; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble F-38043, France.
Rev Sci Instrum ; 85(11): 115104, 2014 Nov.
Article em En | MEDLINE | ID: mdl-25430146
ABSTRACT
Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B4C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L3 edge on a high-Tc superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2014 Tipo de documento: Article