Your browser doesn't support javascript.
loading
Miniaturization of gene transfection assays in 384- and 1536-well microplates.
Li, Jing; Crowley, Samuel T; Duskey, Jason; Khargharia, Sanjib; Wu, Meng; Rice, Kevin G.
Afiliação
  • Li J; Division of Medicinal and Natural Products Chemistry, College of Pharmacy, University of Iowa, Iowa City, IA 52242, USA.
  • Crowley ST; Division of Medicinal and Natural Products Chemistry, College of Pharmacy, University of Iowa, Iowa City, IA 52242, USA.
  • Duskey J; Division of Medicinal and Natural Products Chemistry, College of Pharmacy, University of Iowa, Iowa City, IA 52242, USA.
  • Khargharia S; Division of Medicinal and Natural Products Chemistry, College of Pharmacy, University of Iowa, Iowa City, IA 52242, USA.
  • Wu M; Division of Medicinal and Natural Products Chemistry, College of Pharmacy, University of Iowa, Iowa City, IA 52242, USA; Department of Biochemistry, University of Iowa, Iowa City, IA 52242, USA; University of Iowa High Throughput Screening Facility, University of Iowa, Iowa City, IA 52242, USA.
  • Rice KG; Division of Medicinal and Natural Products Chemistry, College of Pharmacy, University of Iowa, Iowa City, IA 52242, USA. Electronic address: kevin-rice@uiowa.edu.
Anal Biochem ; 470: 14-21, 2015 Feb 01.
Article em En | MEDLINE | ID: mdl-25448623
ABSTRACT
The miniaturization of gene transfer assays to either 384- or 1536-well plates greatly economizes the expense and allows much higher throughput when transfecting immortalized and primary cells compared with more conventional 96-well assays. To validate the approach, luciferase and green fluorescent protein (GFP) reporter gene transfer assays were developed to determine the influence of cell seeding number, transfection reagent to DNA ratios, transfection time, DNA dose, and luciferin dose on linearity and sensitivity. HepG2, CHO, and NIH 3T3 cells were transfected with polyethylenimine (PEI)-DNA in both 384- and 1536-well plates. The results established optimal transfection parameters in 384-well plates in a total assay volume of 35µl and in 1536-well plates in a total assay volume of 8µl. A luciferase assay performed in 384-well plates produced a Z' score of 0.53, making it acceptable for high-throughput screening. Primary hepatocytes were harvested from mouse liver and transfected with PEI DNA and calcium phosphate DNA nanoparticles in 384-well plates. Optimal transfection of primary hepatocytes was achieved on as few as 250cellsperwell in 384-well plates, with CaPO4 proving to be 10-fold more potent than PEI.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transfecção / Microtecnologia Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transfecção / Microtecnologia Idioma: En Ano de publicação: 2015 Tipo de documento: Article