Your browser doesn't support javascript.
loading
Does a non-stemmed constrained condylar prosthesis predispose to early failure of primary total knee arthroplasty?
Deshmukh, Ajit J; Rathod, Parthiv A; Moses, Michael J; Snir, Nimrod; Marwin, Scott E; Dayan, Alan J.
Afiliação
  • Deshmukh AJ; NYU Hospital For Joint Diseases, NYU Langone Medical Center, 301 E 17th Street, New York, NY, 10003, USA. drajitdeshmukh@gmail.com.
  • Rathod PA; VA New York Harbor Healthcare System, 423 E 23rd Street, New York, NY, 10010, USA. drajitdeshmukh@gmail.com.
  • Moses MJ; NYU Hospital For Joint Diseases, NYU Langone Medical Center, 301 E 17th Street, New York, NY, 10003, USA.
  • Snir N; NYU Hospital For Joint Diseases, NYU Langone Medical Center, 301 E 17th Street, New York, NY, 10003, USA.
  • Marwin SE; NYU Hospital For Joint Diseases, NYU Langone Medical Center, 301 E 17th Street, New York, NY, 10003, USA.
  • Dayan AJ; NYU Hospital For Joint Diseases, NYU Langone Medical Center, 301 E 17th Street, New York, NY, 10003, USA.
Knee Surg Sports Traumatol Arthrosc ; 24(10): 3194-3199, 2016 Oct.
Article em En | MEDLINE | ID: mdl-25552405
ABSTRACT

PURPOSE:

The use of unlinked constrained condylar components (CCK) has been extended to primary total knee arthroplasty (TKA); however, there is limited literature on its outcomes. The purpose of this retrospective cohort study was to assess clinical outcomes of one particular design of primary, non-stemmed, unlinked constrained TKA and to compare them with a control group of PS-TKA utilizing the same implant design.

METHODS:

The clinical and radiographic outcomes of 486-cemented, non-stemmed, primary TKA's performed by two surgeons at one institution using similar surgical algorithm, technique and prosthetic design were retrospectively reviewed. Primary TKA components were used in all knees; the only difference between groups was the type of polyethylene inserts used (CCK vs PS). Pre-operative deformity, knee society scores (KSS), range-of-motion (ROM), radiographic data and revision rates were compared.

RESULTS:

Both groups had comparable demographics, pre-operative coronal plane alignment, ROM and KSS. At a mean follow-up of 3.5 years, no difference was found in ROM, KSS, radiographic outcomes and revision rates.

CONCLUSIONS:

Cemented, primary, non-stemmed CCK-TKA offered comparable clinico-radiographic results to PS-TKA at short-term follow-up. Use of a semi-constrained insert without additional stems did not predispose to failure due to aseptic loosening with this implant design. Moreover, the rate of revision due to instability was lowered. LEVEL OF EVIDENCE Retrospective cohort study, Level III.
Assuntos
Palavras-chave
Buscar no Google
Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Falha de Prótese / Artroplastia do Joelho / Prótese do Joelho Idioma: En Ano de publicação: 2016 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Falha de Prótese / Artroplastia do Joelho / Prótese do Joelho Idioma: En Ano de publicação: 2016 Tipo de documento: Article