A region-matching method for pulse transit time estimation: potential for improving the accuracy in determining carotid femoral pulse wave velocity.
Hu, F S; Zhang, Y L; Ma, Z C; Cao, Q Q; Xu, Y B; He, Z J; Sun, Y N.
Afiliação
  • Hu FS; Department of Automation, University of Science and Technology of China, Hefei, PR China.
  • Zhang YL; Research Center for Information Technology of Sports and Health, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, PR China.
  • Ma ZC; Research Center for Information Technology of Sports and Health, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, PR China.
  • Cao QQ; Research Center for Information Technology of Sports and Health, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, PR China.
  • Xu YB; Research Center for Information Technology of Sports and Health, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, PR China.
  • He ZJ; Research Center for Information Technology of Sports and Health, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, PR China.
  • Sun YN; Research Center for Information Technology of Sports and Health, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, PR China.
J Hum Hypertens ; 29(11): 675-82, 2015 Nov.
Article em En | MEDLINE | ID: mdl-25694218
ABSTRACT
Carotid femoral pulse wave velocity (cfPWV) is the 'gold standard' for assessment of arterial stiffness. The reliability of cfPWV measurement depends on the estimation of pulse transit time (PTT). This study aimed to validate a region-matching method for determining PTT and cfPWV against the existing 'foot-to-foot' methods. A cohort of 81 subjects (33 males and 48 females) aged 25-80 (45.1±15.7 years) were studied. PTTs were estimated by the region matching and 'foot-to-foot' methods ('diastole minimum', 'maximum first derivative', 'maximum second derivative' and 'tangent intersection' methods) with manual identification as the reference method and were subsequently used to calculate cfPWV. In a subgroup of 30 individuals, the measurements were repeated after 1 h. There were excellent correlations between cfPWV obtained by the reference method and all the estimated methods (r>0.9, P<0.001 for all), except the diastole minimum method (r=0.793, P<0.001). The region-matching method yielded cfPWV with a better accuracy (mean difference=-0.161 m s(-1), limits of agreement -0.79 to 0.46 m s(-1)) and repeatability (mean difference=-0.228 m s(-1), intraclass correlation coefficient=0.957) comparing with the 'foot-to-foot' methods. These results demonstrate that the proposed region-matching method is more accurate and suitable for PTT estimation and cfPWV measurement.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artérias Carótidas / Artéria Femoral / Doença Arterial Periférica / Rigidez Vascular / Análise de Onda de Pulso Idioma: En Ano de publicação: 2015 Tipo de documento: Article