Your browser doesn't support javascript.
loading
Eye lens dose in interventional cardiology.
Principi, S; Delgado Soler, C; Ginjaume, M; Beltran Vilagrasa, M; Rovira Escutia, J J; Duch, M A.
Afiliação
  • Principi S; Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya, Barcelona, Spain sara.principi@upc.edu.
  • Delgado Soler C; Physics and Radiation Protection Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
  • Ginjaume M; Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya, Barcelona, Spain.
  • Beltran Vilagrasa M; Physics and Radiation Protection Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
  • Rovira Escutia JJ; Physics and Radiation Protection Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
  • Duch MA; Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya, Barcelona, Spain.
Radiat Prot Dosimetry ; 165(1-4): 289-93, 2015 Jul.
Article em En | MEDLINE | ID: mdl-25809107
ABSTRACT
The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y(-1), averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y(-1). This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs) one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y(-1). Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y(-1). It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Cardiologia / Radiologia Intervencionista / Exposição Ocupacional / Cristalino Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Cardiologia / Radiologia Intervencionista / Exposição Ocupacional / Cristalino Idioma: En Ano de publicação: 2015 Tipo de documento: Article