Effects of remedies made in patient setup process on residual setup errors and margins in head and neck cancer radiotherapy based on 2D image guidance.
Kapanen, Mika; Laaksomaa, Marko; Tulijoki, Tapio; Kellokumpu-Lehtinen, Pirkko-Liisa; Hyödynmaa, Simo.
Afiliação
  • Kapanen M; Department of Oncology, Tampere University Hospital (TAUH), PO BOX 2000 (Teiskontie 35), FI-33521 Tampere, Finland ; Department of Medical Physics, Tampere University Hospital (TAUH), PO BOX 2000 (Teiskontie 35), FI-33521 Tampere, Finland.
  • Laaksomaa M; Department of Oncology, Tampere University Hospital (TAUH), PO BOX 2000 (Teiskontie 35), FI-33521 Tampere, Finland.
  • Tulijoki T; Department of Oncology, Tampere University Hospital (TAUH), PO BOX 2000 (Teiskontie 35), FI-33521 Tampere, Finland.
  • Kellokumpu-Lehtinen PL; Department of Oncology, Tampere University Hospital (TAUH), PO BOX 2000 (Teiskontie 35), FI-33521 Tampere, Finland ; School of Medicine, University of Tampere, Tampere, Finland.
  • Hyödynmaa S; Department of Medical Physics, Tampere University Hospital (TAUH), PO BOX 2000 (Teiskontie 35), FI-33521 Tampere, Finland.
Rep Pract Oncol Radiother ; 20(4): 292-8, 2015.
Article em En | MEDLINE | ID: mdl-26109917
AIM: Patient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose. BACKGROUND: RT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results. MATERIALS AND METHODS: The formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1-2, C5-7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula. RESULTS: Systematic residual errors of the landmarks were reduced maximally by 49.8% (p ≤ 0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible. CONCLUSIONS: Remarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.