Your browser doesn't support javascript.
loading
Multi-view stereophotogrammetry for post-mastectomy breast reconstruction.
Ju, Xiangyang; Henseler, Helga; Peng, Matthew Jian-Qiao; Khambay, Balvinder S; Ray, Arup K; Ayoub, Ashraf F.
Afiliação
  • Ju X; Medical Devices Unit, NHS Greater Glasgow and Clyde, Southern General Hospital, Glasgow, G51 4TF, UK. xiangyang.ju@glasgow.ac.uk.
  • Henseler H; Abteilung fr Plastische-, Hand- und Wiederherstellungschirurgie, Medizinische Hochschule Hannover, Carl-Neuberg-Strae 1, 30625, Hannover, Germany.
  • Peng MJ; Department of Joint Surgery, First Affiliated Hospital of Guangzhou Medical University, Guangzhou Research Institute of Computational Orthopedics at Joint Implantation Key Laboratory of Guangdong Province, Guangzhou, China.
  • Khambay BS; Pediatric Dentistry and Orthodontics, Faculty of Dentistry, The University of Hong Kong, Pokfulam, Hong Kong.
  • Ray AK; Canniesburn Plastic Surgery Unit Glasgow, Glasgow Royal Infirmary, 84 Castle Street, Glasgow, G4 0SF, UK.
  • Ayoub AF; Dental Hospital and School, Medical Faculty, MVLS College, Glasgow University, 378 Sauchiehall Street, Glasgow, G2 3JZ, UK.
Med Biol Eng Comput ; 54(2-3): 475-84, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26133282
A multi-view three-dimensional stereophotogrammetry system was developed to capture 3D shape of breasts for breast cancer patients. The patients had received immediate unilateral breast reconstruction after mastectomy by the extended latissimus dorsi flap and without contralateral surgery. In order to capture the whole breast shape including the inframammary fold, the patients were introduced to the imaging room and leaned over the imaging rig to open up the inframammary fold and to expose the entire area of each breast. The imaging system consisted of eight high-resolution ([Formula: see text] pixels) digital cameras and four flash units. The cameras were arranged in four stereo pairs from four different view angles to cover the whole surface of the breasts. The system calibration was carried out ahead of every capture session, and the stereo images were matched to generate four range images to be integrated using an elastic model proposed. A watertight breast mesh model was reconstructed to measure the volume of the breast captured. The accuracy of using the developed multi-view stereophotogrammetry system for breast volume measurement was 11.12cc with SEM 7.74cc, comparing to the measurements of the water displacement method. It was concluded that the 3D stereophotogrammetry image system developed was more reliable than the method of water displacement.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fotogrametria / Mamoplastia / Mastectomia Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fotogrametria / Mamoplastia / Mastectomia Idioma: En Ano de publicação: 2016 Tipo de documento: Article