Randomized Comparison of Actual and Ideal Body Weight for Size Selection of the Laryngeal Mask Airway Classic in Overweight Patients.
Kim, Min-Soo; Lee, Jong Seok; Nam, Sang Beom; Kang, Hyo Jong; Kim, Ji Eun.
Afiliação
  • Kim MS; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
  • Lee JS; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
  • Nam SB; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
  • Kang HJ; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
  • Kim JE; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
J Korean Med Sci ; 30(8): 1197-202, 2015 Aug.
Article em En | MEDLINE | ID: mdl-26240500
ABSTRACT
Size selection of the laryngeal mask airway (LMA) Classic based on actual body weight remains a common practice. However, ideal body weight might allow for a better size selection in obese patients. The purpose of our study was to compare the utility of ideal body weight and actual body weight when choosing the appropriate size of the LMA Classic by a randomized clinical trial. One hundred patients with age 20 to 70 yr, body mass index ≥25 kg/m(2), and the difference between LMA sizes based on actual weight and ideal weight were allocated to insert the LMA Classic using either actual body weight or ideal body weight in a weight-based formula for size selection. After insertion of the device, several variables including insertion parameters, sealing function, fiberoptic imaging, and complications were investigated. The insertion success rate at the first attempt was lower in the actual weight group (82%) than in the ideal weight group (96%), even it did not show significant difference. The ideal weight group had significantly shorter insertion time and easier placement. However, fiberoptic views were significantly better in the actual weight group. Intraoperative complications, sore throat in the recovery room, and dysphonia at postoperative 24 hr occurred significantly less often in the ideal weight group than in the actual weight group. It is suggested that the ideal body weight may be beneficial to the size selection of the LMA Classic in overweight patients (Clinical Trial Registry, NCT 01843270).