Time-resolved optically stimulated luminescence of Al2O3:C for ion beam therapy dosimetry.
Yukihara, Eduardo G; Doull, Brandon A; Ahmed, Md; Brons, Stephan; Tessonnier, Thomas; Jäkel, Oliver; Greilich, Steffen.
Afiliação
  • Yukihara EG; Physics Department, Oklahoma State University, 145 Physical Sciences II, Stillwater, OK 74078, USA.
Phys Med Biol ; 60(17): 6613-38, 2015 Sep 07.
Article em En | MEDLINE | ID: mdl-26270884
ABSTRACT
The objective of this study was to characterize the time-resolved (TR) optically stimulated luminescence (OSL) from Al2O3C detectors and investigate methodologies to improve the accuracy of these detectors in ion beam therapy dosimetry, addressing the reduction in relative response to high linear energy transfer (LET) particles common to solid-state detectors. Al2O3C OSL detectors (OSLDs) were exposed to proton, (4)He, (12)C and (16)O beams in 22 particle/energy combinations and read using a custom-built TR-OSL reader. The OSL response rOSL, relative to (60)Co gamma dose to water, and the ratio between the UV and blue OSL emission bands of Al2O3C (UV/blue ratio) were determined as a function of the LET. Monte-Carlo simulations with the multi-purpose interaction and transport code FLUKA were used to estimate the absorbed doses and particle energy spectra in the different irradiation conditions. The OSL responses rOSL varied from 0.980 (0.73 keV µm(-1)) to 0.288 (120.8 keV µm(-1)). The OSL UV/blue ratio varied by a factor of two in the investigated LET range, but the variation for (12)C beams was only 11%. OSLDs were also irradiated at different depths of carbon ion spread-out Bragg peaks (SOBPs), where it was shown that doses could be obtained with an accuracy of ± 2.0% at the entrance channel and within the SOBP using correction factors calculated based on the OSL responses obtained in this study. The UV/blue ratio did not allow accurate estimation of the dose-averaged LET for (12)C SOBPs, although the values obtained can be explained with the data obtained in this study and the additional information provided by the Monte-Carlo simulations. The results demonstrate that accurate OSLD dosimetry can be performed in ion beam therapy using appropriate corrections for the OSL response.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Luminescência / Óxido de Alumínio / Terapia com Prótons Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Luminescência / Óxido de Alumínio / Terapia com Prótons Idioma: En Ano de publicação: 2015 Tipo de documento: Article