Your browser doesn't support javascript.
loading
Out of Hours Emergency Computed Tomography Brain Studies: Comparison of Standard 3 Megapixel Diagnostic Workstation Monitors With the iPad 2.
Salati, Umer; Leong, Sum; Donnellan, John; Kok, Hong Kuan; Buckley, Orla; Torreggiani, William.
Afiliação
  • Salati U; Department of Radiology, Tallaght Hospital, Dublin, Ireland. Electronic address: umersalati@gmail.com.
  • Leong S; Department of Radiology, Tallaght Hospital, Dublin, Ireland.
  • Donnellan J; Department of Radiology, Tallaght Hospital, Dublin, Ireland.
  • Kok HK; Department of Radiology, Tallaght Hospital, Dublin, Ireland.
  • Buckley O; Department of Radiology, Tallaght Hospital, Dublin, Ireland.
  • Torreggiani W; Department of Radiology, Tallaght Hospital, Dublin, Ireland.
Can Assoc Radiol J ; 66(4): 363-7, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26387729
ABSTRACT

PURPOSE:

The purpose was to compare performance of diagnostic workstation monitors and the Apple iPad 2 (Cupertino, CA) in interpretation of emergency computed tomography (CT) brain studies.

METHODS:

Two experienced radiologists interpreted 100 random emergency CT brain studies on both on-site diagnostic workstation monitors and the iPad 2 via remote access. The radiologists were blinded to patient clinical details and to each other's interpretation and the study list was randomized between interpretations on different modalities. Interobserver agreement between radiologists and intraobserver agreement between modalities was determined and Cohen kappa coefficients calculated for each. Performance with regards to urgent and nonurgent abnormalities was assessed separately.

RESULTS:

There was substantial intraobserver agreement of both radiologists between the modalities with overall calculated kappa values of 0.959 and 0.940 in detecting acute abnormalities and perfect agreement with regards to hemorrhage. Intraobserver agreement kappa values were 0.939 and 0.860 for nonurgent abnormalities. Interobserver agreement between the 2 radiologists for both diagnostic monitors and the iPad 2 was also substantial ranging from 0.821-0.860.

CONCLUSIONS:

The iPad 2 is a reliable modality in the interpretation of CT brain studies in them emergency setting and for the detection of acute and chronic abnormalities, with comparable performance to standard diagnostic workstation monitors.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encefalopatias / Interpretação de Imagem Assistida por Computador / Sistemas de Informação em Radiologia / Telerradiologia / Computadores de Mão / Plantão Médico / Serviços Médicos de Emergência / Tomografia Computadorizada Multidetectores Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encefalopatias / Interpretação de Imagem Assistida por Computador / Sistemas de Informação em Radiologia / Telerradiologia / Computadores de Mão / Plantão Médico / Serviços Médicos de Emergência / Tomografia Computadorizada Multidetectores Idioma: En Ano de publicação: 2015 Tipo de documento: Article