Your browser doesn't support javascript.
loading
THE CHALLENGE OF CIEMAT INTERNAL DOSIMETRY SERVICE FOR ACCREDITATION ACCORDING TO ISO/IEC 17025 STANDARD, FOR IN VIVO AND IN VITRO MONITORING AND DOSE ASSESSMENT OF INTERNAL EXPOSURES.
Lopez, M A; Martin, R; Hernandez, C; Navarro, J F; Navarro, T; Perez, B; Sierra, I.
Afiliação
  • Lopez MA; Radiation Dosimetry Unit, CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, Avda. Complutense 40, 28040 Madrid, Spain ma.lopez@ciemat.es.
  • Martin R; Radiation Dosimetry Unit, CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, Avda. Complutense 40, 28040 Madrid, Spain.
  • Hernandez C; Radiation Dosimetry Unit, CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, Avda. Complutense 40, 28040 Madrid, Spain.
  • Navarro JF; Radiation Dosimetry Unit, CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, Avda. Complutense 40, 28040 Madrid, Spain.
  • Navarro T; Radiation Dosimetry Unit, CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, Avda. Complutense 40, 28040 Madrid, Spain.
  • Perez B; Radiation Dosimetry Unit, CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, Avda. Complutense 40, 28040 Madrid, Spain.
  • Sierra I; Radiation Dosimetry Unit, CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, Avda. Complutense 40, 28040 Madrid, Spain.
Radiat Prot Dosimetry ; 170(1-4): 31-4, 2016 Sep.
Article em En | MEDLINE | ID: mdl-26433182
ABSTRACT
The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Radiometria / Exposição Ocupacional Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Radiometria / Exposição Ocupacional Idioma: En Ano de publicação: 2016 Tipo de documento: Article