Your browser doesn't support javascript.
loading
Ventricular cycle length irregularity affects the correlation between ventricular rate and coronary flow in isolated, Langendorff perfused guinea pig hearts.
Takács, Hedvig; Kui, Péter; Farkas, Attila S; Sarusi, Annamária; Forster, Tamás; Papp, Julius Gy; Varró, András; Curtis, Michael J; Shattock, Michael J; Farkas, András.
Afiliação
  • Takács H; Second Department of Medicine and Cardiology Centre, Faculty of Medicine, University of Szeged, Szeged, Hungary.
  • Kui P; Department of Pharmacology and Pharmacotherapy, Faculty of Medicine, University of Szeged, Szeged, Hungary.
  • Farkas AS; Second Department of Medicine and Cardiology Centre, Faculty of Medicine, University of Szeged, Szeged, Hungary.
  • Sarusi A; Department of Pharmacology and Pharmacotherapy, Faculty of Medicine, University of Szeged, Szeged, Hungary.
  • Forster T; Second Department of Medicine and Cardiology Centre, Faculty of Medicine, University of Szeged, Szeged, Hungary.
  • Papp JG; Department of Pharmacology and Pharmacotherapy, Faculty of Medicine, University of Szeged, Szeged, Hungary; MTA-SZTE Research Group for Cardiovascular Pharmacology, Hungarian Academy of Sciences, Hungary.
  • Varró A; Department of Pharmacology and Pharmacotherapy, Faculty of Medicine, University of Szeged, Szeged, Hungary.
  • Curtis MJ; King's College, London, UK.
  • Shattock MJ; King's College, London, UK.
  • Farkas A; Second Department of Medicine and Cardiology Centre, Faculty of Medicine, University of Szeged, Szeged, Hungary. Electronic address: farkas.andras@med.u-szeged.hu.
Article em En | MEDLINE | ID: mdl-26455880
ABSTRACT

INTRODUCTION:

Heart rate affects coronary flow, but the mechanism is complex. The relationship between rhythm and flow is unclear, especially in experimental settings used for determining drug actions. The present study examined whether ventricular irregularity influences coronary flow independently of heart rate.

METHODS:

Guinea pig hearts were perfused (Langendorff mode) at constant pressure. Hypokalemic Krebs solution facilitated spontaneous development of arrhythmias. The ECG, left ventricular and perfusion pressures were recorded, and the coronary flow was measured. Beat-to-beat ventricular cycle length variability was quantified. Hearts were retrospectively allocated to arbitrary 'Low' or 'High' RR variability groups.

RESULTS:

A positive linear correlation was found between mean ventricular rate and coronary flow. The slope of the regression line was significantly greater in the 'High' versus 'Low' RR variability group, with greater coronary flow values in the 'High' RR variability group in the physiological heart rate range. During regular rhythm, left ventricular pressure exceeded perfusion pressure and prevented coronary perfusion at peak systole. However, ventricular irregularity significantly increased the number of beats in which left ventricular pressure remained below perfusion pressure, facilitating coronary perfusion.

DISCUSSION:

In isolated hearts, cycle length irregularity increases the slope of the positive linear correlation between mean ventricular rate and coronary flow via producing beats in which left ventricular pressure remains below perfusion pressure. This means that changes in rhythm have the capacity to influence coronary flow independently of heart rate in isolated hearts perfused at constant pressure, which should be noted in drug studies on arrhythmias performed in Langendorff hearts.