Your browser doesn't support javascript.
loading
Diffusion-Weighted Imaging in 3.0 Tesla Breast MRI: Diagnostic Performance and Tumor Characterization Using Small Subregions vs. Whole Tumor Regions of Interest.
Arponen, Otso; Arponent, Otso; Sudah, Mazen; Masarwah, Amro; Taina, Mikko; Rautiainen, Suvi; Könönen, Mervi; Sironen, Reijo; Kosma, Veli-Matti; Sutela, Anna; Hakumäki, Juhana; Vanninen, Ritva.
Afiliação
  • Arponen O; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland; University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland.
  • Sudah M; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland.
  • Masarwah A; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland; University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland.
  • Taina M; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland; University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland.
  • Rautiainen S; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland; University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland.
  • Könönen M; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland.
  • Sironen R; Kuopio University Hospital, Department of Pathology, Kuopio University Hospital, Kuopio, Finland; University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Pathology and Forensic Medicine, Kuopio University Hospital, Kuopio, Finland; University of East
  • Kosma VM; Kuopio University Hospital, Department of Pathology, Kuopio University Hospital, Kuopio, Finland; University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Pathology and Forensic Medicine, Kuopio University Hospital, Kuopio, Finland; University of East
  • Sutela A; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland.
  • Hakumäki J; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland.
  • Vanninen R; Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland; University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland; Univ
PLoS One ; 10(10): e0138702, 2015.
Article em En | MEDLINE | ID: mdl-26458106
ABSTRACT

INTRODUCTION:

Apparent diffusion coefficient (ADC) values are increasingly reported in breast MRI. As there is no standardized method for ADC measurements, we evaluated the effect of the size of region of interest (ROI) to diagnostic utility and correlation to prognostic markers of breast cancer.

METHODS:

This prospective study was approved by the Institutional Ethics Board; the need for written informed consent for the retrospective analyses of the breast MRIs was waived by the Chair of the Hospital District. We compared diagnostic accuracy of ADC measurements from whole-lesion ROIs (WL-ROIs) to small subregions (S-ROIs) showing the most restricted diffusion and evaluated correlations with prognostic factors in 112 consecutive patients (mean age 56.2±11.6 years, 137 lesions) who underwent 3.0-T breast MRI.

RESULTS:

Intra- and interobserver reproducibility were substantial (κ = 0.616-0.784; Intra-Class Correlation 0.589-0.831). In receiver operating characteristics analysis, differentiation between malignant and benign lesions was excellent (area under curve 0.957-0.962, cut-off ADC values for WL-ROIs 0.87×10-3 mm2s-1; S-ROIs 0.69×10-3 mm2s-1, P<0.001). WL-ROIs/S-ROIs achieved sensitivities of 95.7%/91.3%, specificities of 89.5%/94.7%, and overall accuracies of 89.8%/94.2%. In S-ROIs, lower ADC values correlated with presence of axillary metastases (P = 0.03), high histological grade (P = 0.006), and worsened Nottingham Prognostic Index Score (P<0.05). In both ROIs, ADC values correlated with progesterone receptors and advanced stage (P<0.01), but not with HER2, estrogen receptors, or Ki-67.

CONCLUSIONS:

ADC values assist in breast tumor characterization. Small ROIs were more accurate than whole-lesion ROIs and more frequently associated with prognostic factors. Cut-off values differed significantly depending on measurement procedure, which should be recognized when comparing results from the literature. Instead of using a whole lesion covering ROI, a small ROI could be advocated in diffusion-weighted imaging.