Your browser doesn't support javascript.
loading
Effect of Axial Length on Macular Ganglion Cell Complex Thickness and on Early Glaucoma Diagnosis by Spectral-Domain Optical Coherence Tomography.
Nakanishi, Hideo; Akagi, Tadamichi; Hangai, Masanori; Kimura, Yugo; Suda, Kenji; Hasegawa, Tomoko; Yamada, Hiroshi; Yoshikawa, Munemitsu; Morooka, Satoshi; Ikeda, Hanako Ohashi; Yoshimura, Nagahisa.
Afiliação
  • Nakanishi H; *Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto †Department of Ophthalmology, Saitama Medical University, Moroyama, Saitama, Japan.
J Glaucoma ; 25(5): e481-90, 2016 05.
Article em En | MEDLINE | ID: mdl-26550972
ABSTRACT

PURPOSE:

To investigate the effects of the axial length (AL)-related ocular magnification on the thickness of the macular ganglion cell complex (mGCC), and the diagnostic accuracy of the built-in normative database of the spectral-domain optical coherence tomographic (SD-OCT) instrument for early glaucoma detection.

METHODS:

This retrospective study included 41 eyes with early primary open-angle glaucoma and 36 normal eyes. The mGCC thickness within a 20-degree circle, equivalent to a 6 mm diameter in the Gullstrand model eye, was measured in the SD-OCT images. The magnification effect was corrected using Bennett formula, and the mGCC thickness within the actual 6 mm diameter circle was determined.

RESULTS:

In normal eyes, the inferior corrected mGCC was significantly correlated with the AL (ß=-0.40, P=0.028), but correction for the magnification reduced the correlation. In 38 nonhighly myopic eyes, the sensitivity and specificity of the SD-OCT's significance maps for distinguishing early glaucoma were 95.0% and 94.4% when using either the uncorrected or the corrected mGCC. In 39 highly myopic eyes, the diagnostic accuracy was lower when using the uncorrected mGCC thickness (sensitivity was 95.2% and specificity was 44.4%), and was not improved when using the corrected mGCC (81.0% and 61.1%, respectively).

CONCLUSIONS:

The inferior mGCC was thinner in eyes with longer AL. The accuracy of the diagnosis with the SD-OCT built-in normative database for early glaucoma was not improved significantly by the correction of the AL-associated magnification in highly myopic eyes. Evaluation of highly myopic eyes with the nonhighly myopic normative database can lead to misdiagnosis.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Células Ganglionares da Retina / Glaucoma de Ângulo Aberto / Comprimento Axial do Olho / Fibras Nervosas Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Células Ganglionares da Retina / Glaucoma de Ângulo Aberto / Comprimento Axial do Olho / Fibras Nervosas Idioma: En Ano de publicação: 2016 Tipo de documento: Article