Your browser doesn't support javascript.
loading
Five-year experience of cementless Oxford unicompartmental knee replacement.
Pandit, H G; Campi, S; Hamilton, T W; Dada, O D; Pollalis, S; Jenkins, C; Dodd, C A F; Murray, D W.
Afiliação
  • Pandit HG; Nuffield Orthopaedic Centre, Windmill Road, Oxford, UK.
  • Campi S; Nuffield Department for Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Windmill Road, Oxford, UK.
  • Hamilton TW; Nuffield Department for Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Windmill Road, Oxford, UK.
  • Dada OD; Nuffield Department for Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Windmill Road, Oxford, UK. thomas.hamilton@ndorms.ox.ac.uk.
  • Pollalis S; Nuffield Orthopaedic Centre, Windmill Road, Oxford, UK.
  • Jenkins C; Nuffield Orthopaedic Centre, Windmill Road, Oxford, UK.
  • Dodd CAF; Nuffield Orthopaedic Centre, Windmill Road, Oxford, UK.
  • Murray DW; Nuffield Orthopaedic Centre, Windmill Road, Oxford, UK.
Knee Surg Sports Traumatol Arthrosc ; 25(3): 694-702, 2017 Mar.
Article em En | MEDLINE | ID: mdl-26611902
ABSTRACT

PURPOSE:

Cementless unicompartmental knee replacement (UKR) was introduced to address some of the problems that can occur following cemented UKR. The aim of this study was to report the 5-year experience of the first 512 medial cementless Oxford UKR implanted by two surgeons for the recommended indications.

METHODS:

The first consecutive 512 cementless Phase 3 Oxford UKRs implanted by two surgeons for the recommended indications between June 2004 and October 2013 were prospectively identified and followed up independently. All the procedures were carried out through a minimally invasive approach without eversion or dislocation of the patella. Patients were assessed clinically pre-operatively and at 1, 2, 5, 7 and 10 years after surgery with functional outcome scores and radiographs.

RESULTS:

There were eight reoperations of which six were revisions giving a 5-year survival of 98 % (95 % CI 94-100 %). At a mean follow-up of 3.4 years (1.0-10.2), the mean OKS was 43 (SD 7), AKSS (objective) was 81 (SD 13), and AKSS (functional) was 86 (SD 17). The first 120 cases had a minimum follow-up of 5 years (mean 5.9; range 5-10.2). In these patients, the mean OKS was 41 (SD 8), AKSS (objective) was 81 (SD 14), and AKSS (functional) was 82 (SD 18). There were no femoral radiolucencies and no complete tibial radiolucencies. 11 % of tibial components had partial radiolucent lines; the remaining 89 % had no radiolucencies.

CONCLUSION:

The clinical results are as good as or better than those previously reported for cemented fixation. The radiographic results are better with secure bony attachment to the implants in every case. LEVEL OF EVIDENCE IV.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Desenho de Prótese / Artroplastia do Joelho / Osteoartrite do Joelho / Prótese do Joelho Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Desenho de Prótese / Artroplastia do Joelho / Osteoartrite do Joelho / Prótese do Joelho Idioma: En Ano de publicação: 2017 Tipo de documento: Article