Your browser doesn't support javascript.
loading
High Precision Determination of the ß Decay Q(EC) Value of (11)C and Implications on the Tests of the Standard Model.
Gulyuz, K; Bollen, G; Brodeur, M; Bryce, R A; Cooper, K; Eibach, M; Izzo, C; Kwan, E; Manukyan, K; Morrissey, D J; Naviliat-Cuncic, O; Redshaw, M; Ringle, R; Sandler, R; Schwarz, S; Sumithrarachchi, C S; Valverde, A A; Villari, A C C.
Afiliação
  • Gulyuz K; National Superconducting Cyclotron Laboratory, East Lansing, Michigan 48824, USA.
  • Bollen G; Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824, USA.
  • Brodeur M; Facility for Rare Isotope Beams, East Lansing, Michigan 48824, USA.
  • Bryce RA; Department of Physics, University of Notre Dame, Notre Dame, Indiana 46556, USA.
  • Cooper K; Department of Physics, Central Michigan University, Mount Pleasant, Michigan 48859, USA.
  • Eibach M; National Superconducting Cyclotron Laboratory, East Lansing, Michigan 48824, USA.
  • Izzo C; Department of Chemistry, Michigan State University, East Lansing, Michigan 48824, USA.
  • Kwan E; National Superconducting Cyclotron Laboratory, East Lansing, Michigan 48824, USA.
  • Manukyan K; National Superconducting Cyclotron Laboratory, East Lansing, Michigan 48824, USA.
  • Morrissey DJ; Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824, USA.
  • Naviliat-Cuncic O; National Superconducting Cyclotron Laboratory, East Lansing, Michigan 48824, USA.
  • Redshaw M; Department of Physics, University of Notre Dame, Notre Dame, Indiana 46556, USA.
  • Ringle R; National Superconducting Cyclotron Laboratory, East Lansing, Michigan 48824, USA.
  • Sandler R; Department of Chemistry, Michigan State University, East Lansing, Michigan 48824, USA.
  • Schwarz S; National Superconducting Cyclotron Laboratory, East Lansing, Michigan 48824, USA.
  • Sumithrarachchi CS; Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824, USA.
  • Valverde AA; National Superconducting Cyclotron Laboratory, East Lansing, Michigan 48824, USA.
  • Villari AC; Department of Physics, Central Michigan University, Mount Pleasant, Michigan 48859, USA.
Phys Rev Lett ; 116(1): 012501, 2016 Jan 08.
Article em En | MEDLINE | ID: mdl-26799013
ABSTRACT
We report the determination of the Q(EC) value of the mirror transition of (11)C by measuring the atomic masses of (11)C and (11)B using Penning trap mass spectrometry. More than an order of magnitude improvement in precision is achieved as compared to the 2012 Atomic Mass Evaluation (Ame2012) [Chin. Phys. C 36, 1603 (2012)]. This leads to a factor of 3 improvement in the calculated Ft value. Using the new value, Q(EC)=1981.690(61) keV, the uncertainty on Ft is no longer dominated by the uncertainty on the Q(EC) value. Based on this measurement, we provide an updated estimate of the Gamow-Teller to Fermi mixing ratio and standard model values of the correlation coefficients.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article