Your browser doesn't support javascript.
loading
A mix-and-read drop-based in vitro two-hybrid method for screening high-affinity peptide binders.
Cui, Naiwen; Zhang, Huidan; Schneider, Nils; Tao, Ye; Asahara, Haruichi; Sun, Zhiyi; Cai, Yamei; Koehler, Stephan A; de Greef, Tom F A; Abbaspourrad, Alireza; Weitz, David A; Chong, Shaorong.
Afiliação
  • Cui N; School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
  • Zhang H; School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
  • Schneider N; Department of Cell Biology, Key Laboratory of Cell Biology, Ministry of Public Health, and Key Laboratory of Medical Cell Biology, Ministry of Education, China Medical University, Shenyang 110001, China.
  • Tao Y; Ecole Supérieure de Biotechnologie de Strasbourg, Boulevard Sébastien Brant, 67400, Illkirch, France.
  • Asahara H; New England Biolabs, Inc. 240 County Road, Ipswich, MA 01938, USA.
  • Sun Z; School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
  • Cai Y; School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China.
  • Koehler SA; New England Biolabs, Inc. 240 County Road, Ipswich, MA 01938, USA.
  • de Greef TF; New England Biolabs, Inc. 240 County Road, Ipswich, MA 01938, USA.
  • Abbaspourrad A; School of Pharmacy, Second Military Medical University, Shanghai 200433, China.
  • Weitz DA; School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
  • Chong S; Institute for Complex Molecular Systems, Department of Biomedical Engineering Eindhoven University of Technology Den Dolech 2, 5600 MB Eindhoven, The Netherlands.
Sci Rep ; 6: 22575, 2016 Mar 04.
Article em En | MEDLINE | ID: mdl-26940078
Drop-based microfluidics have recently become a novel tool by providing a stable linkage between phenotype and genotype for high throughput screening. However, use of drop-based microfluidics for screening high-affinity peptide binders has not been demonstrated due to the lack of a sensitive functional assay that can detect single DNA molecules in drops. To address this sensitivity issue, we introduced in vitro two-hybrid system (IVT2H) into microfluidic drops and developed a streamlined mix-and-read drop-IVT2H method to screen a random DNA library. Drop-IVT2H was based on the correlation between the binding affinity of two interacting protein domains and transcriptional activation of a fluorescent reporter. A DNA library encoding potential peptide binders was encapsulated with IVT2H such that single DNA molecules were distributed in individual drops. We validated drop-IVT2H by screening a three-random-residue library derived from a high-affinity MDM2 inhibitor PMI. The current drop-IVT2H platform is ideally suited for affinity screening of small-to-medium-sized libraries (10(3)-10(6)). It can obtain hits within a single day while consuming minimal amounts of reagents. Drop-IVT2H simplifies and accelerates the drop-based microfluidics workflow for screening random DNA libraries, and represents a novel alternative method for protein engineering and in vitro directed protein evolution.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas do Sistema de Duplo-Híbrido / Microfluídica / Escherichia coli Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas do Sistema de Duplo-Híbrido / Microfluídica / Escherichia coli Idioma: En Ano de publicação: 2016 Tipo de documento: Article