Your browser doesn't support javascript.
loading
Stereoselective method to quantify bupropion and its three major metabolites, hydroxybupropion, erythro-dihydrobupropion, and threo-dihydrobupropion using HPLC-MS/MS.
Masters, Andrea R; McCoy, Michael; Jones, David R; Desta, Zeruesenay.
Afiliação
  • Masters AR; Indiana University School of Medicine, Indiana University Melvin and Bren Simon Cancer Center, RR208, 699 Riley Hospital Drive, Indianapolis, IN 46202, United States. Electronic address: argrove@iupui.edu.
  • McCoy M; Phenomenex, 411 Madrid Avenue, Torrance, CA 90501, United States. Electronic address: MichaelMc@phenomenex.com.
  • Jones DR; Department of Medicine, Division of Clinical Pharmacology, RR 208, 699 Riley Hospital Drive, Indianapolis, IN 46202, United States. Electronic address: drjones1@iu.edu.
  • Desta Z; Department of Medicine, Division of Clinical Pharmacology, R2 402, 950 West Walnut Avenue, Indianapolis, IN 46202, United States. Electronic address: zdesta@iu.edu.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1015-1016: 201-208, 2016 Mar 15.
Article em En | MEDLINE | ID: mdl-26946423
Bupropion metabolites formed via oxidation and reduction exhibit pharmacological activity, but little is known regarding their stereoselective disposition. A novel stereoselective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to separate and quantify enantiomers of bupropion, 4-hydroxybupropion, and erythro- and threo-dihydrobupropion. Liquid-liquid extraction was implemented to extract all analytes from 50 µL human plasma. Acetaminophen (APAP) was used as an internal standard. The analytes were separated on a Lux 3 µ Cellulose-3 250×4.6 mm column by methanol: acetonitrile: ammonium bicarbonate: ammonium hydroxide gradient elution and monitored using an ABSciex 5500 QTRAP triple-quadrupole mass spectrometer equipped with electrospray ionization probe in positive mode. Extraction efficiency for all analytes was ≥70%. The stability at a single non-extracted concentration for over 48 h at ambient temperature resulted in less than 9.8% variability for all analytes. The limit of quantification (LOQ) for enantiomers of bupropion and 4-hydroxybupropion was 0.3 ng/mL, while the LOQ for enantiomers of erythro- and threo-hydrobupropion was 0.15 ng/mL. The intra-day precision and accuracy estimates for enantiomers of bupropion and its metabolites ranged from 3.4% to 15.4% and from 80.6% to 97.8%, respectively, while the inter-day precision and accuracy ranged from 6.1% to 19.9% and from 88.5% to 99.9%, respectively. The current method was successfully implemented to determine the stereoselective pharmacokinetics of bupropion and its metabolites in 3 healthy volunteers administered a single 100mg oral dose of racemic bupropion. This novel, accurate, and precise HPLC-MS/MS method should enhance further research into bupropion stereoselective metabolism and drug interactions.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Bupropiona / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Bupropiona / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2016 Tipo de documento: Article