EEG in postanoxic coma: Prognostic and diagnostic value.
Clin Neurophysiol
; 127(4): 2047-55, 2016 Apr.
Article
em En
| MEDLINE
| ID: mdl-26971488
ABSTRACT
Evolution of the EEG background pattern is a robust contributor to prediction of poor or good outcome of comatose patients after cardiac arrest. At 24h, persistent isoelectricity, low voltage activity, or burst-suppression with identical bursts predicts a poor outcome without false positives. Rapid recovery toward continuous patterns within 12h is strongly associated with a good neurological outcome. Predictive values are highest in the first 24h, despite the use of mild therapeutic hypothermia and sedative medication. Studies on reactivity or mismatch negativity have not included the EEG background pattern. Therefore, the additional predictive value of reactivity parameters remains unclear. Whether or not treatment of electrographic status epilepticus improves outcome is studied in the randomized multicenter Treatment of Electroencephalographic STatus epilepticus After cardiopulmonary Resuscitation (TELSTAR) trial (NCT02056236).
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Coma
/
Hipóxia-Isquemia Encefálica
/
Eletroencefalografia
/
Parada Cardíaca
Idioma:
En
Ano de publicação:
2016