Your browser doesn't support javascript.
loading
Ultra-trace levels analysis of microcystins and nodularin in surface water by on-line solid-phase extraction with high-performance liquid chromatography tandem mass spectrometry.
Balest, Lydia; Murgolo, Sapia; Sciancalepore, Lucia; Montemurro, Patrizia; Abis, Pier Paolo; Pastore, Carlo; Mascolo, Giuseppe.
Afiliação
  • Balest L; Acquedotto Pugliese S.p.A., Area Controllo Qualità, Direzione Operativa (DOPRI), Viale Emanuele Orlando, Bari, 70121, Italy.
  • Murgolo S; Consiglio Nazionale delle Ricerche, Istituto di Ricerca Sulle Acque, Viale F. De Blasio 5, Bari, 70132, Italy.
  • Sciancalepore L; Acquedotto Pugliese S.p.A., Area Controllo Qualità, Direzione Operativa (DOPRI), Viale Emanuele Orlando, Bari, 70121, Italy.
  • Montemurro P; Acquedotto Pugliese S.p.A., Area Controllo Qualità, Direzione Operativa (DOPRI), Viale Emanuele Orlando, Bari, 70121, Italy.
  • Abis PP; Acquedotto Pugliese S.p.A., Area Controllo Qualità, Direzione Operativa (DOPRI), Viale Emanuele Orlando, Bari, 70121, Italy.
  • Pastore C; Consiglio Nazionale delle Ricerche, Istituto di Ricerca Sulle Acque, Viale F. De Blasio 5, Bari, 70132, Italy.
  • Mascolo G; Consiglio Nazionale delle Ricerche, Istituto di Ricerca Sulle Acque, Viale F. De Blasio 5, Bari, 70132, Italy. giuseppe.mascolo@ba.irsa.cnr.it.
Anal Bioanal Chem ; 408(15): 4063-71, 2016 Jun.
Article em En | MEDLINE | ID: mdl-27052778
ABSTRACT
An on-line solid phase extraction coupled with high-performance liquid chromatography in tandem with mass spectrometry (on-line SPE/HPLC/MS-MS) method for the determination of five microcystins and nodularin in surface waters at submicrogram per liter concentrations has been optimized. Maximum recoveries were achieved by carefully optimizing the extraction sample volume, loading solvent, wash solvent, and pH of the sample. The developed method was also validated according to both UNI EN ISO IEC 17025 and UNICHIM guidelines. Specifically, ten analytical runs were performed at three different concentration levels using a reference mix solution containing the six analytes. The method was applied for monitoring the concentrations of microcystins and nodularin in real surface water during a sampling campaign of 9 months in which the ELISA method was used as standard official method. The results of the two methods were compared showing good agreement when the highest concentration values of MCs were found. Graphical abstract An on-line SPE/HPLC/MS-MS method for the determination of five microcystins and nodularin in surface waters at sub µg L(-1) was optimized and compared with ELISA assay method for real samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Cromatografia Líquida de Alta Pressão / Microcistinas / Espectrometria de Massas em Tandem / Extração em Fase Sólida Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Cromatografia Líquida de Alta Pressão / Microcistinas / Espectrometria de Massas em Tandem / Extração em Fase Sólida Idioma: En Ano de publicação: 2016 Tipo de documento: Article