Your browser doesn't support javascript.
loading
3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study.
Eikendal, Anouk L M; Blomberg, Björn A; Haaring, Cees; Saam, Tobias; van der Geest, Rob J; Visser, Fredy; Bots, Michiel L; den Ruijter, Hester M; Hoefer, Imo E; Leiner, Tim.
Afiliação
  • Eikendal AL; Department of Radiology (E01.132), University Medical Center, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands. a.l.m.eikendal@umcutrecht.nl.
  • Blomberg BA; Department of Radiology (E01.132), University Medical Center, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
  • Haaring C; Department of Radiology (E01.132), University Medical Center, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
  • Saam T; Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377, Munich, Germany.
  • van der Geest RJ; Division of Image Processing, Department of Radiology, 1-C2S Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands.
  • Visser F; Department of Radiology (E01.132), University Medical Center, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
  • Bots ML; Philips Healthcare, Veenpluis 4-6, 5684PC, Best, The Netherlands.
  • den Ruijter HM; Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
  • Hoefer IE; Laboratory of Experimental Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
  • Leiner T; Laboratory of Clinical Chemistry and Hematology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
J Cardiovasc Magn Reson ; 18: 20, 2016 Apr 14.
Article em En | MEDLINE | ID: mdl-27075677
ABSTRACT

BACKGROUND:

Pre-clinical detection of atherosclerosis enables personalized preventive strategies in asymptomatic individuals. Cardiovascular magnetic resonance (CMR) has evolved as an attractive imaging modality for studying atherosclerosis in vivo. Yet, the majority of aortic CMR studies and proposed sequences to date have been performed at 1.5 tesla using 2D BB techniques and a slice thickness of 4-5 mm. Here, we evaluate for the first time the reproducibility of an isotropic, T1-weighted, three-dimensional, black-blood, CMR VISTA sequence (3D-T1-BB-VISTA) for quantification of aortic wall characteristics in healthy, young adults.

METHODS:

In 20 healthy, young adults (10 males, mean age 31.3 years) of the AMBITYON cohort study the descending thoracic aorta was imaged with a 3.0 T MR system using the 3D-T1-BB-VISTA sequence. The inter-scan, inter-rater and intra-rater reproducibility of aortic lumen, total vessel and wall area and mean and maximum wall thickness was evaluated using Bland-Altman analyses and Intraclass Correlation Coefficients (ICC). Based on these findings, sample sizes for detecting differences in aortic wall characteristics between groups were calculated.

RESULTS:

For each studied parameter, the inter-scan, inter-rater and intra-rater reproducibility was excellent as indicated by narrow limits of agreement and high ICCs (ranging from 0.76 to 0.99). Sample sizes required to detect a 5% difference in aortic wall characteristics between two groups were 203, 126, 136, 68 and 153 per group for lumen area, total vessel area and vessel wall area and for mean and maximum vessel wall thickness, respectively.

CONCLUSION:

The 3D-T1-BB-VISTA sequence provides excellent reproducibility for quantification of aortic wall characteristics and can detect small differences between groups with reasonable sample sizes. Hence, it may be a valuable tool for assessment of the subtle vascular wall changes of early atherosclerosis in asymptomatic populations.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aorta Torácica / Aortografia / Ensaios Clínicos como Assunto / Tamanho da Amostra / Angiografia por Ressonância Magnética Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aorta Torácica / Aortografia / Ensaios Clínicos como Assunto / Tamanho da Amostra / Angiografia por Ressonância Magnética Idioma: En Ano de publicação: 2016 Tipo de documento: Article