Your browser doesn't support javascript.
loading
Subtomogram analysis using the Volta phase plate.
Khoshouei, Maryam; Pfeffer, Stefan; Baumeister, Wolfgang; Förster, Friedrich; Danev, Radostin.
Afiliação
  • Khoshouei M; Max-Planck Institute of Biochemistry, Department of Molecular Structural Biology, Am Klopferspitz 18, 82152 Martinsried, Germany.
  • Pfeffer S; Max-Planck Institute of Biochemistry, Department of Molecular Structural Biology, Am Klopferspitz 18, 82152 Martinsried, Germany.
  • Baumeister W; Max-Planck Institute of Biochemistry, Department of Molecular Structural Biology, Am Klopferspitz 18, 82152 Martinsried, Germany.
  • Förster F; Max-Planck Institute of Biochemistry, Department of Molecular Structural Biology, Am Klopferspitz 18, 82152 Martinsried, Germany; Cryo-Electron Microscopy, Bijvoet Center for Biomolecular Research, Utrecht University, Padualaan 8, 3584 CH Utrecht, The Netherlands. Electronic address: foerster@bioche
  • Danev R; Max-Planck Institute of Biochemistry, Department of Molecular Structural Biology, Am Klopferspitz 18, 82152 Martinsried, Germany. Electronic address: danev@biochem.mpg.de.
J Struct Biol ; 197(2): 94-101, 2017 02.
Article em En | MEDLINE | ID: mdl-27235783
Cryo-electron tomography (CET) and subtomogram analysis allow studying the structures of macromolecular complexes in their natural context. The radiation sensitivity of vitrified biological specimens and the resulting low signal-to-noise ratio (SNR) in CET limit the amount of structural information that can be mined from tomographic data. The Volta phase plate (VPP) has emerged as an effective means to increase the SNR and hence contrast compared to 'conventional' defocus-based phase contrast transmission electron microscopy (CTEM). Here, we assess the performance of the VPP compared to CTEM in subtomogram analysis, using the mammalian 80S ribosome as a test case. Accurate focusing is the major factor for achieving high resolution with the VPP, as highlighted by a comparison of slightly different focusing strategies. From only 1400 subtomograms, the VPP yields a subtomogram average of the mammalian 80S ribosome at 9.6Å resolution without laborious contrast transfer function (CTF) correction. The subtomogram averages obtained using CTEM approaches are comparable, but suffer from lower signal transfer in certain frequency bands due to the oscillations of the CTF. Our study demonstrates that the VPP is a valuable tool for subtomogram analysis, because it enables improved performance and efficiency in terms of structure localization and number of subtomograms required for a given resolution.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Microscopia Crioeletrônica / Microscopia Eletrônica de Transmissão Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Microscopia Crioeletrônica / Microscopia Eletrônica de Transmissão Idioma: En Ano de publicação: 2017 Tipo de documento: Article