Your browser doesn't support javascript.
loading
Hydrolytic anaerobic reactor and aerated constructed wetland systems for municipal wastewater treatment - HIGHWET project.
Pascual, A; de la Varga, D; Arias, C A; Van Oirschot, D; Kilian, R; Álvarez, J A; Soto, M.
Afiliação
  • Pascual A; a Department of Physical Chemistry and Chemical Engineering I , University of A Coruña , A Coruña , Galiza , Spain.
  • de la Varga D; b AIMEN , Porriño - Pontevedra , Spain.
  • Arias CA; c Sedaqua (Spin-off from University of A Coruña) , O Porriño, Pontevedra , Spain.
  • Van Oirschot D; d Department of Bioscience , Aarhus University , Aarhus , Denmark.
  • Kilian R; e Rietland bvba , Minderhout , Belgium.
  • Álvarez JA; f Kilian Water , Bryrup , Denmark.
  • Soto M; b AIMEN , Porriño - Pontevedra , Spain.
Environ Technol ; 38(2): 209-219, 2017 Jan.
Article em En | MEDLINE | ID: mdl-27241268
ABSTRACT
The HIGHWET project combines the hydrolytic up-flow sludge bed (HUSB) anaerobic digester and constructed wetlands (CWs) with forced aeration for decreasing the footprint and improving effluent quality. The HIGHWET plant in A Coruña (NW of Spain) treating municipal wastewater consists of a HUSB and four parallel subsurface horizontal flow (HF) CWs. HF1, HF2 and HF3 units are fitted with forced aeration, while the control HF4 is not aerated. All the HF units are provided with effluent recirculation, but different heights of gravel bed (0.8 m in HF1 and HF2, and 0.5 m in HF3 and HF4) are implemented. Besides, a tobermorite-enriched material was added in the HF2 unit in order to improve phosphorus removal. The HUSB 76-89% of total suspended solids (TSS) and about 40% of chemical oxygen demand (COD) and biological oxygen demand (BOD). Aerated HF units reached above 96% of TSS, COD and BOD at a surface loading rate of 29-47 g BOD5/m2·d. An aeration regime ranging from 5 h on/3 h off to 3 h on/5 h off was found to be adequate to optimize nitrogen removal, which ranged from 53% to 81%. Average removal rates of 3.4 ± 0.4 g total nitrogen (TN)/m2·d and 12.8 ± 3.7 g TN/m3·d were found in the aerated units, being 5.5 and 4.1 times higher than those of the non-aerated system. The tobermorite-enriched HF2 unit showed a distinct higher phosphate (60-67%) and total phosphorus (54%) removal.
Assuntos
Palavras-chave
Buscar no Google
Base de dados: MEDLINE Assunto principal: Eliminação de Resíduos Líquidos / Reatores Biológicos / Áreas Alagadas Idioma: En Ano de publicação: 2017 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Eliminação de Resíduos Líquidos / Reatores Biológicos / Áreas Alagadas Idioma: En Ano de publicação: 2017 Tipo de documento: Article