Your browser doesn't support javascript.
loading
Simultaneous assessment of endogenous thiol compounds by LC-MS/MS.
Sun, Yao; Yao, Tong; Guo, Xiucai; Peng, Ying; Zheng, Jiang.
Afiliação
  • Sun Y; School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning 110016, PR China.
  • Yao T; School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning 110016, PR China.
  • Guo X; School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning 110016, PR China.
  • Peng Y; School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning 110016, PR China. Electronic address: yingpeng1999@163.com.
  • Zheng J; Key Laboratory of Structure-Based Drug Design & Discovery of Ministry of Education, Shenyang Pharmaceutical University, Shenyang, Liaoning 110016, PR China; Center for Developmental Therapeutics, Seattle Children's Research Institute, Division of Gastroenterology and Hepatology, Department of Pe
J Chromatogr B Analyt Technol Biomed Life Sci ; 1029-1030: 213-221, 2016 Sep 01.
Article em En | MEDLINE | ID: mdl-27442797
ABSTRACT
Biological thiol compounds are very important molecules that participate in various physiological events. Alteration in levels of endogenous thiols has been suggested as a biomarker of early stage of pathological changes. We reported a chemical derivatization- and LC-MS/MS-based approach to simultaneously determine thiol compounds including glutathione (GSH), cysteine (Cys), N-acetyl cysteine (NAC), homocysteine (Hcy), and cysteinylglycine (CysGly) in biological samples. Thiol-containing samples were derivatized with monobromobimane (mBrB) at room temperature, followed by LC-MS/MS analysis. Assessment of the analytes with baseline separation was completed within 10min, using a gradient elution on a C18 reversed-phase column. Excellent linearity was observed for all analytes over their concentration ranges of 1-400µM. The lowest limits of detection (S/N=3) in a range from 0.31fmol (for NAC) to 4.98fmol (for CysGly) were achieved. The results indicate that this approach was sensitive, selective, and well suited for high-throughput quantitative determination of the biological thiols.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Acetilcisteína / Cromatografia Líquida de Alta Pressão / Cisteína / Dipeptídeos / Glutationa / Homocisteína / Fígado Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Acetilcisteína / Cromatografia Líquida de Alta Pressão / Cisteína / Dipeptídeos / Glutationa / Homocisteína / Fígado Idioma: En Ano de publicação: 2016 Tipo de documento: Article