Capillary electrophoresis and phenylboronic acid solid phase extraction for the determination of S-adenosylmethionine/S-adenosylhomocysteine ratio in human urine.
Ivanov, Alexander Vladimirovich; Virus, Edward Danielevich; Nikiforova, Ksenya Alexandrovna; Kushlinskii, Nicolai Evgenevich; Luzyanin, Boris Petrovich; Maksimova, Marina Yurievna; Piradov, Mikhail Aleksanrovich; Kubatiev, Aslan Amirkhanovich.
Afiliação
  • Ivanov AV; Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology,", Moscow, Russia. Ivanov_av82@mail.ru.
  • Virus ED; Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology,", Moscow, Russia.
  • Nikiforova KA; Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology,", Moscow, Russia.
  • Kushlinskii NE; N. N. Blokhin Russian Cancer Research Center, Moscow, Russia.
  • Luzyanin BP; Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology,", Moscow, Russia.
  • Maksimova MY; Research Center of Neurology, Moscow, Russia.
  • Piradov MA; Research Center of Neurology, Moscow, Russia.
  • Kubatiev AA; Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology,", Moscow, Russia.
Electrophoresis ; 37(20): 2663-2669, 2016 10.
Article em En | MEDLINE | ID: mdl-27445270
ABSTRACT
An approach that allows direct analysis of the ratio of S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH) by using CE is presented. The analytes were extracted on phenylboronic acid phase and eluted with 100 mmol/L HCl. CE separation of the analytes took place in the transient isotachophoresis mode with addition of NaCl and meglumine to the samples. The sensitivity (S/N = 3) and quantification limit (S/N = 10) of the method were 0.07 and 0.2 µmol/L, respectively, using a silica capillary with 50 µm internal diameter and 30.5 cm total length. The BGE was 0.02 mol/L Tris with 1 mol/L HCOOH (pH 2.2), and the separation voltage was 15-17 kV. Accuracy of SAM and SAH analysis in urine was 96 and 105%, respectively; interday precision for the SAM/SAH ratio was within 6%. The theoretical plate number exceeded a million. Total analysis time was 8.5 min.