Your browser doesn't support javascript.
loading
OpEx - a validated, automated pipeline optimised for clinical exome sequence analysis.
Ruark, Elise; Münz, Márton; Clarke, Matthew; Renwick, Anthony; Ramsay, Emma; Elliott, Anna; Seal, Sheila; Lunter, Gerton; Rahman, Nazneen.
Afiliação
  • Ruark E; The Institute of Cancer Research, London, Division of Genetics &Epidemiology, Sutton SM2 5NG, UK.
  • Münz M; Wellcome Trust Centre for Human Genetics, Roosevelt Drive, Oxford OX3 7BN, UK.
  • Clarke M; The Institute of Cancer Research, London, Division of Genetics &Epidemiology, Sutton SM2 5NG, UK.
  • Renwick A; The Institute of Cancer Research, London, Division of Genetics &Epidemiology, Sutton SM2 5NG, UK.
  • Ramsay E; The Institute of Cancer Research, London, Division of Genetics &Epidemiology, Sutton SM2 5NG, UK.
  • Elliott A; The Institute of Cancer Research, London, Division of Genetics &Epidemiology, Sutton SM2 5NG, UK.
  • Seal S; The Institute of Cancer Research, London, Division of Genetics &Epidemiology, Sutton SM2 5NG, UK.
  • Lunter G; Wellcome Trust Centre for Human Genetics, Roosevelt Drive, Oxford OX3 7BN, UK.
  • Rahman N; The Institute of Cancer Research, London, Division of Genetics &Epidemiology, Sutton SM2 5NG, UK.
Sci Rep ; 6: 31029, 2016 08 03.
Article em En | MEDLINE | ID: mdl-27485037
ABSTRACT
We present an easy-to-use, open-source Optimised Exome analysis tool, OpEx (http//icr.ac.uk/opex) that accurately detects small-scale variation, including indels, to clinical standards. We evaluated OpEx performance with an experimentally validated dataset (the ICR142 NGS validation series), a large 1000 exome dataset (the ICR1000 UK exome series), and a clinical proband-parent trio dataset. The performance of OpEx for high-quality base substitutions and short indels in both small and large datasets is excellent, with overall sensitivity of 95%, specificity of 97% and low false detection rate (FDR) of 3%. Depending on the individual performance requirements the OpEx output allows one to optimise the inevitable trade-offs between sensitivity and specificity. For example, in the clinical setting one could permit a higher FDR and lower specificity to maximise sensitivity. In contexts where experimental validation is not possible, minimising the FDR and improving specificity may be a preferable trade-off for slightly lower sensitivity. OpEx is simple to install and use; the whole pipeline is run from a single command. OpEx is therefore well suited to the increasing research and clinical laboratories undertaking exome sequencing, particularly those without in-house dedicated bioinformatics expertise.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article