Your browser doesn't support javascript.
loading
Evaluation of Pastorex meningitis kit performance for the rapid identification of Neisseria meningitidis serogroup C in Nigeria.
Uadiale, Kennedy; Bestman, Agatha; Kamau, Charity; Caugant, Dominique A; Greig, Jane.
Afiliação
  • Uadiale K; Médecins sans Frontières, Sokoto, Nigeria.
  • Bestman A; Médecins sans Frontières, Sokoto, Nigeria.
  • Kamau C; Médecins sans Frontières, Amsterdam, Netherlands.
  • Caugant DA; WHO Collaborating Centre for Reference and Research on Meningococci, Norwegian Institute of Public Health, Oslo, Norway.
  • Greig J; Manson Unit, Médecins Sans Frontières, London, UK jane.greig@london.msf.org.
Trans R Soc Trop Med Hyg ; 110(7): 381-5, 2016 07.
Article em En | MEDLINE | ID: mdl-27496511
BACKGROUND: Neisseria meningitidis serogroup C (NmC) has caused outbreaks in Nigeria of increasing size in three consecutive years since 2013. Rapid diagnostic tests (RDTs) for meningitis can facilitate quick identification of the causative pathogen; Pastorex can detect N. meningitidis serogroups A, C (NmC), Y/W135, N. meningitidis serogroup B/Escherichia coli K1, Haemophilus influenzae type b (Hib), Streptococcus pneumoniae, and group B Streptococcus. There is no published field evaluation of Pastorex in the identification of NmC. We report our experience with Pastorex in detecting NmC in field conditions. METHODS: During sequential outbreaks of NmC in Nigeria in 2013, 2014 and 2015, cerebrospinal fluid (CSF) was collected from suspected cases of meningitis that met the case definition. Pastorex latex agglutination rapid test was done in the field and trans-isolate media were inoculated with CSF for culture and/or PCR, which was used as the reference standard for 63 paired samples. RESULTS: The sensitivity of Pastorex for NmC was 80.0% (95% CI 65.4-90.4%) and the specificity was 94.4% (95% CI 72.7-99.9%). The positive likelihood ratio (LR) was 14.4 (95% CI 2.1-97.3) and negative LR was 0.2 (95% CI 0.1-0.4). The positive and negative predictive values (PPV and NPV) were 97.3% (95% CI 85.8-99.9) and 65.4% (95% CI 44.3-82.8), respectively, with a prevalence estimate of 71.4% (95% CI 58.6-82.1). CONCLUSION: Pastorex showed good performance in detecting NmC under field conditions. Prepositioning Pastorex at peripheral health facilities during non-epidemic periods is constrained by a short shelf-life of 1 month after the kit is opened. There is need for development of RDTs that are cheaper and with less challenging requirements for storage and usage.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Testes de Fixação do Látex / Sorogrupo / Meningite Meningocócica / Neisseria meningitidis Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Testes de Fixação do Látex / Sorogrupo / Meningite Meningocócica / Neisseria meningitidis Idioma: En Ano de publicação: 2016 Tipo de documento: Article